:: Volume 11, Issue 1 (4-2022) ::
ieijqp 2022, 11(1): 1-9 Back to browse issues page
A new method for using the UV-Visible spectrum of oil to evaluate the paper insulation quality of used transformers
Reza Emadifar1 , Navid Taghizadegan Kalantari * 1, Vahid Behjat1 , Reza Najjar2
1- Department of Electrical Engineering, Azarbaijan Shahid Madani University, Tabriz, Iran
2- Polymer Research Laboratory, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
Abstract:   (2357 Views)
Power transformers are one of the most vital and expensive devices in the electricity transmission and distribution network. Therefore, monitoring and evaluating their operational condition is a vital issue for managers in the electricity industry to prevent failure in the power distribution network, maintain their highly reliable performance, manage their assets, and increase the productivity of the network. The results of many research works have indicated that the useful life of a transformer is directly related to the life of its paper insulation system. The measurement of furan compounds released into the insulation oil due to the degradation of cellulose in insulation paper is a common method for assessing the operational condition of the transformers. High-performance liquid chromatography (HPLC) has been introduced as one of the relatively well-established methods for measuring furan compounds according to ASTM-D-5837. Regarding the need for high profession and expertise for operating and using HPLC system as well as the high price of this system, it is inevitable to develop fast, simple, cheap, and user-friendly systems and techniques with high precision without any need for high operator profession. The use of ultraviolet-visible (UV-Vis) spectroscopy has been proposed as a new, effective, and economically preferable alternative method for measuring the concentration of cellulose degradation compounds in insulation oil. However, the excessive turbidity of the oil in older transformers caused by the cellulose degradation products exerts a relatively high ambiguity on the results of this technique and may make its results somehow unreliable. In this paper, a new method is proposed to improve the optical spectrum results and solve the turbidity problem of the used oil samples. This method is composed of the dilution of oil samples with adequate solvents to overcome their high turbidity in combination with the fuzzy logic to evaluate the UV-Vis results. The proposed method was implemented on oil samples taken from 23 transformers. A fuzzy logic algorithm is used to estimate the furan compound contents from the optical spectrum of the oil. The comparison between the results of the method developed in this work and the results of HPLC analysis reveals a relative error as low as 11%, proving that the developed method can be a safe, fast, and cost-effective solution for electricity distribution network operators to assess and monitor the status of network transformers.
Keywords: Transformers, Transformer Insulator Evaluation, Furan, Spectroscopy, High Pressure Liquid Chromatography, Paper Insulation, Fuzzy Logic
Full-Text [PDF 1055 kb]   (968 Downloads)    
Type of Study: Research |
Received: 2021/05/8 | Accepted: 2022/01/17 | Published: 2022/04/26
References
1. Abu-Siada, A. (2011). Correlation of furan concentration and spectral response of transformer oil-using expert systems. IET Science, Measurement & Technology, 5(5), pp. 183-188. [DOI:10.1049/iet-smt.2011.0017]
2. Abu-Siada, A., Lai, S.P. & Islam, S., (2009). Remnant life estimation of power transformer using oil UV-Vis spectral response. IEEE/PES Power Systems Conference and Exposition, pp. 1-5. [DOI:10.1109/PSCE.2009.4840111]
3. Abu-Siada, A., Lai, S.P. & Islam, S.M., (2012). A novel fuzzy-logic approach for furan estimation in transformer oil. IEEE Transactions on Power Delivery, 27(2), pp.469-474. [DOI:10.1109/TPWRD.2012.2186986]
4. Ancuța-Mihaela, A. C. I. U., NIȚU, M. C. NICOLA, M. NICOLA, C.-I., & LĂZĂRESCU F. (2020). Complementary Analysis of the Degree of Polymerization Based on Chemical Markers 2-Furaldehyde and Methanol Using the Fuzzy Logic. 21st International Symposium on Electrical Apparatus & Technologies (SIELA), pp. 1-6. IEEE. [DOI:10.1109/SIELA49118.2020.9167088]
5. Arshad, M., & Islam, S. M. (2007). Power transformer condition assessment using oil UV-spectrophotometry. Annual Report-Conference on Electrical Insulation and Dielectric Phenomena, pp. 611-614. [DOI:10.1109/CEIDP.2007.4451646]
6. Behjat, V., Emadifar, R., Pourhossein, M., Rao, U.M., Fofana, I., & Najjar, R. (2021). Improved Monitoring and Diagnosis of Transformer Solid Insulation Using Pertinent Chemical Indicators. Energies, 14(13), pp. 3977-3930. [DOI:10.3390/en14133977]
7. Cheim, L., Platts, D., Prevost, T. & Xu, S., (2012). Furan analysis for liquid power transformers". IEEE Electrical Insulation Magazine, 28(2), pp. 8-21.‌ [DOI:10.1109/MEI.2012.6159177]
8. Das, N., Abu-Siada, A. & Islam, S., (2012). New approach to estimate furan contents in transformer oil using spectroscopic analysis. The 22nd Australasian Universities Power Engineering Conference (AUPEC), pp. 1-4.
9. De Pablo, A., (1997). Interpretation of furanic compounds analysis-degradation models". CIGRE WG D1.01.03, former WG 15-01, Task Force 03.
10. Ghoneim, S. S. (2019). The Degree of Polymerization in a Prediction Model of Insulating Paper and the Remaining Life of Power Transformers, Energies, 14(3), pp. 670-684. [DOI:10.3390/en14030670]
11. Hussain, K., & Karmakar, S. (2014). Condition assessment of transformer oil using UV-Visible spectroscopy. The 18th National Power Systems Conference (NPSC), pp. 1-5. [DOI:10.1109/NPSC.2014.7103841]
12. Karthik, R., Raja, T.S.R. & Iruthayarajan, M.W., (2013). Investigations of furanic derivatives in transformer oil using ultra-violet light absorption property. IET Electric Power Applications, 7(2), pp. 123-130. [DOI:10.1049/iet-epa.2012.0177]
13. Kumar, A. (2007). Ageing of cellulose in mineral-oil insulated transformers. CIGRE Task Force D1.01.10.
14. Lai, Sin P., Abu-Siada, A. Islam, S. M. & Lenco. G. (2008). Correlation between UV-Vis spectral response and furan measurement of transformer oil. International Conference on Condition Monitoring and Diagnosis, IEEE, pp. 659-662. [DOI:10.1109/CMD.2008.4580372]
15. Ortiz, F., Fernández, C., Santisteban, A., Delgado, F. & Ortiz, A., (2016). Estimating the age of power transformers using the concentration of furans in dielectric oil. Renewable Energy and Power Quality Journal, 1(14), pp. 1011-1015. [DOI:10.24084/repqj14.557]
16. حسینی، س ش. (1399). «بررسی الکتریکی و حرارتی نانو سیالات با پایه روغن ترانسفورماتور»، نشریه علمی و پژوهشی کیفیت و بهره‌وری صنعت برق ایران، 9(1)، صص48-39.
17. عمادی فر، ر.، و بهجت، و.، (۱۸ تا ۲۰ آذر ۱۳۹۸) «پایش و ارزیابی وضعیت عایق کاغذی ترانسفورماتورهای توزیع با استفاده از روش‌های شیمیایی نوین (مطالعه موردی ترانسفورماتورهای توزیع تبریز)»، سی و چهارمین کنفرانس بین‌المللی برق، پژوهشگاه نیرو، تهران، ایران.
18. نفیسی، ح.، عابدی، م.، و قره پتیان، گ. (1391). «مکانیابی تخلیه جزئی با استفاده از مدل مشروح ترانسفورماتورها به کمک شبکه عصبی FAM و بیزین»، نشریه علمی و پژوهشی کیفیت و بهره وری صنعت برق ایران، ۱(۱)، صص 57-46.
19. نفیسی، ح.، عسکریان ابیانه، ح.، و عابدی، م. (1393). «مدل‌سازی احتمالی میزان کاهش عمر ترانسفورماتورهای توزیع با در نظر گرفتن نفوذ خودروهای اتصال الکتریکی هایبریدی»، نشریه علمی و پژوهشی کیفیت و بهره‌وری صنعت برق ایران، ۳(۵)، صص 7-1.


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Emadifar R, Taghizadegan Kalantari N, Behjat V, Najjar R. A new method for using the UV-Visible spectrum of oil to evaluate the paper insulation quality of used transformers. ieijqp 2022; 11 (1) :1-9
URL: http://ieijqp.ir/article-1-798-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 11, Issue 1 (4-2022) Back to browse issues page
نشریه علمی- پژوهشی کیفیت و بهره وری صنعت برق ایران Iranian Electric Industry Journal of Quality and Productivity
Persian site map - English site map - Created in 0.06 seconds with 40 queries by YEKTAWEB 4645