:: Volume 3, Issue 1 (9-2014) ::
ieijqp 2014, 3(1): 38-45 Back to browse issues page
Analysis of the effect of unmanned operation of substations on the reliability indices of substation
Iraj Zaker1 , Mohammad ebrahim Hajiabadi * 2, Habib Rajabi Mashhadi3
1- khorasan regional electric company
2- Hakim sabzevari unuversity
3- Ferdowsi university of mashhad
Abstract:   (8528 Views)
The purpose of this paper is to investigate the reliability of the unmanned substations which operated remotely by dispatching center. In order to achieve this goal, this paper proposes a two step modeling method. At the first step, firstly we reviewed the reliability of substation equipment and its modeling. Then, by analyzing statistical reports, the stochastic behaviors of substation equipment were reviewed. The goal of this step is to investigate the behavior of equipment reliability parameters after applying unmanned operation if substations. This depends on the automation level, statistical studies and professional experience of engineers. In the second step, with the help of minimal cut-set method, the reliability of substation at two modes of operation of it (conventional & unmanned) has been studied. This paper shows that the level of reliability of unmanned substations is more than twice the level of reliability of conventional substations
Keywords: substation, unmanned operation, reliability, minimal Cut-set
Full-Text [PDF 477 kb]   (2309 Downloads)    
Type of Study: Research | Subject: Special
Received: 2014/01/15 | Accepted: 2014/08/6 | Published: 2014/09/6


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

zaker I, Hajiabadi M E, Rajabi Mashhadi H. Analysis of the effect of unmanned operation of substations on the reliability indices of substation. ieijqp 2014; 3 (1) :38-45
URL: http://ieijqp.ir/article-1-147-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 3, Issue 1 (9-2014) Back to browse issues page
نشریه علمی- پژوهشی کیفیت و بهره وری صنعت برق ایران Iranian Electric Industry Journal of Quality and Productivity
Persian site map - English site map - Created in 0.06 seconds with 40 queries by YEKTAWEB 4645