ieijqp 2015, 4(1): 58-66 Back to browse issues page
A Novel Phase Drift Correction Method To Online Estimation of Thévenin Equivalent in Power System
Hossein Kazemi Karegar * 1, Bahman Alinejad1
1- Faculty of Electrical Engineering
Abstract:   (8619 Views)
In this paper, a novel method is proposed to estimate the online value of Thévenin Equivalent (TE) from a generator bus using Phasor Measurement. Three consecutive phasor values of voltage and current (V,I) recorded at generator bus are used to estimate the TE. To synchronize the consecutive phasors to the same reference and correcting the phase drift, a virtual vector in triangulation method is proposed. It is shown that the triangle construction in case of inconsistency is possible when the virtual vector is used. In addition, a new method to eliminate the noisy or irrelevant measurements is introduced. The algorithm is tested on standard IEEE 30-Bus network that is simulated in time domain by DigSILENT software both in steady state and transient conditions. The algorithm performance also is investigated and approved in the university protection laboratory with a typical test case system. The interesting results approve the novelty and efficiency of the proposed method
Keywords: Thévenin Equivalent (TE), Phasor Measurement Units (PMU), Triangulation Method, Phase Drift
Full-Text [PDF 1329 kb]   (1517 Downloads)    
Type of Study: Applicable | Subject: Special
Received: 2015/04/17 | Accepted: 2015/08/29 | Published: 2015/09/9


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Kazemi Karegar H, Alinejad B. A Novel Phase Drift Correction Method To Online Estimation of Thévenin Equivalent in Power System. ieijqp 2015; 4 (1) :58-66
URL: http://ieijqp.ir/article-1-242-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 4, Issue 1 (9-2015) Back to browse issues page
نشریه علمی- پژوهشی کیفیت و بهره وری صنعت برق ایران Iranian Electric Industry Journal of Quality and Productivity
Persian site map - English site map - Created in 0.06 seconds with 40 queries by YEKTAWEB 4645