ieijqp 2019, 8(1): 72-81 Back to browse issues page
Comparison of the effects of two flatness based control methods for STATCOM on improving stability in power systems including DFIG based wind farms
Hamid Ghaedi1 , Ghazanfar Shahgholian *1 , Mahnaz Hashemi1
1- Islamic Azad University
Abstract:   (4427 Views)
Power grids are complex, interconnected and nonlinear systems, and this will be more severe when they are subjected to high wind resources penetration. Static synchronous compensators (STATCOM) are used to improve voltage regulation and to meet grid codes in power systems, including doubly fed induction generators (DFIG) based wind farms. Despite the nonlinear nature of STATCOM, the conventional control method in them is based on linear PI controllers with constant gains, which they cannot guarantee the optimal performance for STATCOM. In this paper, a comparison has been performed between two nonlinear control methods based on differential flatness theory for static synchronous compensators in the WSCC system includes DFIG based wind farms and simulation results demonstrate the effective performance of both methods in comparison with the conventional linear control method.
 
Keywords: Static synchronous compensator, Low Voltage Ride through, Flatness based feedback linearization control, Flatness based adaptive control
Full-Text [PDF 1810 kb]   (1016 Downloads)    
Type of Study: Research |
Received: 2019/03/19 | Accepted: 2019/07/10 | Published: 2019/08/28
References
1. [1] Shahgholian, G., "Analysis and Simulation of Dyna-m¬ic Performance for DFIG-Based Wind Farm Conn¬ec¬ted to A Distribution System", Energy Equipment and Systems, Vol. 6, No. 2, pp. 117-130, June 2018.
2. [2] شمس¬نیا، علی، حسینی، سیدحسین، دانیالی، سعید، "مدلسازی و شبیه‌سازی اینورتر هیبرید با منابع انرژی تجدید پذیر سلول خورشیدی و توربین بادی مجهز به الگوریتم MPPT بهبودیافته"، نشریه کیفیت و بهره¬وری صنعت برق ایران، سال: 1، شماره: 2، ص: 8-18، زمستان 1391.
3. [3] Rather, Z.H., Chen, Z., Thøgersen, P., "Dynamic Reactive Power Compensation of Large-Scale Wind Integrated Power System", IEEE Trans. on Power Systems, Vol. 30, No.5, pp. 2516-2526, Sep. 2015. [DOI:10.1109/TPWRS.2014.2365632]
4. [4] Pao, L.Y., Johnson, K.E., "Control of wind turbines", IEEE Control Systems Magazine, Vol. 31, No. 2, pp. 44-62, April 2011. [DOI:10.1109/MCS.2010.939962]
5. [5] Jafari, A., Shahgholian, G., "Analysis and Simulation of A Sliding Mode Controller for Mechanical Part of A Doubly-Fed Induction Generator Based Wind Turbine", IET Generation, Transmission and Distrib¬u¬tion, Vol. 11, No. 10, pp. 2677-2688, July 2017. [DOI:10.1049/iet-gtd.2016.1969]
6. [6] صفایی، آرمان، حسینیان، سیدحسین، عسکریان ابیانه، حسین، "بهبود قابلیت گذر از خطای توربین بادی دارای ژنراتور القایی تغذیه دوگانه در ریز شبکه"، نشریه کیفیت و بهره¬وری صنعت برق ایران، سال: 6، شماره: 12، ص: 34-45، پاییز و زمستان 1396.
7. [7] Edrah, M., Lo, K.L., Anaya-lara, O., "Impacts of high penetration of DFIG wind turbines on rotor angle stability of power systems", IEEE Trans. on Sustainable Energy, Vol. 6, No. 3, pp. 759-766, July 2015. [DOI:10.1109/TSTE.2015.2412176]
8. [8] Mohaghegh Montazeri, M., Xu, D., Yuwen, B., "Improved Low Voltage Ride Through capability of wind farm using STATCOM", Proceeding of the IEEE/IEMDC, pp. 813-818, May 2011. [DOI:10.1109/IEMDC.2011.5994918]
9. [9] Mukhopadhyay, B., Mandal, R.K., "Voltage compensation using PSO-PI controlled STATCOM in a DFIG-based grid-connected wind energy system", International Conference on Electrical Power and Energy Systems, ICEPES 2016, pp. 88-93, May 2017. [DOI:10.1109/ICEPES.2016.7915911]
10. [10] Kerrouche, K.D.E., Wang, L., Abdelkader, A., Boumediene, L., Van Den Bossche, A., "Fractional-Order Sliding Mode Control for D-STATCOM Connected Wind Farm Based DFIG Under Voltage Unbalanced", Arabian Journal for Science and Engineering, Vol. 44, No. 3, pp. 2265-2280, March 2019. [DOI:10.1007/s13369-018-3412-y]
11. [11] Sun, X., Wu, W., "A new sliding mode control of STATCOM and its effects on wind farm", Proceedings of the IEEE/EMEIT, Vol. 6, pp. 2938-2941, Harbin, China, Sep. 2011. [DOI:10.1109/EMEIT.2011.6023035]
12. [12] Xu, Y., Li, F., "Adaptive PI Control of STATCOM for Voltage Regulation", IEEE Trans on Power delivery, Vol. 29, No. 3, pp. 1002-1011, June. 2014. [DOI:10.1109/TPWRD.2013.2291576]
13. [13] Hemeida, M.G., Rezk, H., Hamada, M.M., "A comprehensive comparison of STATCOM versus SVC-based fuzzy controller for stability improvement of wind farm connected to multi-machine power system", Electrical Engineering, Vol. 100, No. 2, pp. 935-951, May. 2017. [DOI:10.1007/s00202-017-0559-6]
14. [14] Shahgholian, G., Izadpanahi, N., "Improving the performance of wind turbine equipped with DFIG using STATCOM based on input-output feedback linearization controller", Energy Equipment and Systems, Vol. 4, No.1, pp. 65-79, June 2016.
15. [15] Saxena, N.K., Kumar, A., "Reactive power control in decentralized hybrid power system with STATCOM using GA, ANN and ANFIS methods", International Journal of Electrical Power and Energy Systems, Vol. 83, No. , pp. 175-187, Dec. 2016. [DOI:10.1016/j.ijepes.2016.04.009]
16. [16] Lingling, F, Miao, Z. Modeling and Analysis of Doubly Fed Induction Generator Wind Energy Systems. Academic Press, 2015.
17. [17] Kerrouche, K.D.E., Abdelkader, M., Boumediene, L., Van Den Bossche, A.P.M., "A comprehensive review of LVRT capability and sliding mode control of grid-connected wind-turbine-driven doubly fed induction generator", Automatika, Vol. 57, No. 4, pp. 922-935, May. 2017. [DOI:10.7305/automatika.2017.05.1813]
18. [18] Ghorbanian, M.J., Goodarzvand, F., Pourdaryaei, A., Mahadi, W.N.L., "Mitigating voltage sag by implementing STATCOM on DFIG-based wind farms connected to a power system", Proceeding of the IEEE/ICE2T, pp. 131-136, Kuala Lumpur, Malaysia, Aug. 2014. [DOI:10.1109/ICE2T.2014.7006233]
19. [19] Singh, B., Saha, R., Chandra, A., Al-haddad, K., "Static synchronous compensators (STATCOM): a review", IET Power Electronics, Vol. 2, No. , pp. 297-324, July. 2009. [DOI:10.1049/iet-pel.2008.0034]
20. [20] Hingorani, N.G., Gyugyi, L., "Understanding FACTS: Concepts and Technology of Flexible AC transmission system" IEEE press 2000. [DOI:10.1109/9780470546802]
21. [21] Shahnia, F, Sumedha, R, Ghosh, A. Static Compensators (STATCOMs) in Power Systems. Springer Press 2014 [DOI:10.1007/978-981-287-281-4]
22. [22] Wang, K., Crow, M.L., "Power system voltage regulation via STATCOM internal nonlinear control", IEEE Trans on Power Systems, Vol. 26, No. 3, pp. 1252-1262, Aug. 2011. [DOI:10.1109/TPWRS.2010.2072937]
23. [23] Gensior A., Sira-ramírez, H., Rudolph, J., Güldner, H., "On Some Nonlinear Current Controllers for Three-Phase Boost Rectifiers", IEEE Trans on Industrial Electronics, Vol. 56, No. 2, pp. 360-370, Feb. 2009. [DOI:10.1109/TIE.2008.2003370]
24. [24] Fliess, M., Levine, J., Martin, P., Rouchon, P., "Flatness and defect of non-linear systems: Introductory theory and examples", International Journal of Control, Vol. 61, No. 6, pp. 1327-1361, June. 1995. [DOI:10.1080/00207179508921959]
25. [25] Song, E., Lynch, A.F., Dinavahi, V., "Experimental validation of Nonlinear Control for a Voltage Source Converter", IEEE Trans on Control Systems Technology, Vol. 17, No. 5, pp. 1135-1144, Sep. 2009. [DOI:10.1109/TCST.2008.2001741]
26. [26] Xu, Y., Li, F., Jin, Z., Huang, C., "Flatness-based adaptive control (FBAC) for STATCOM", Electric Power Systems Research, Vol. 122, No, pp. 76-85, May. 2015. [DOI:10.1016/j.epsr.2014.12.023]


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Ghaedi H, Shahgholian G, Hashemi M. Comparison of the effects of two flatness based control methods for STATCOM on improving stability in power systems including DFIG based wind farms. ieijqp 2019; 8 (1) :72-81
URL: http://ieijqp.ir/article-1-617-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 8, Issue 1 (9-2019) Back to browse issues page
نشریه علمی- پژوهشی کیفیت و بهره وری صنعت برق ایران Iranian Electric Industry Journal of Quality and Productivity
Persian site map - English site map - Created in 0.1 seconds with 38 queries by YEKTAWEB 4704