<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Electric Industry Journal of Quality and Productivity</title>
<title_fa>نشریه کیفیت و بهره وری صنعت برق ایران</title_fa>
<short_title>ieijqp</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ieijqp.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2344</journal_id_issn>
<journal_id_issn_online>2717-1639</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61186/ieijqp</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1403</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2024</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>13</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>طراحی و توسعه ماژول نرم افزاری پیکربندی بهینه شبکه توزیع در بستر سامانه اطلاعات جغرافیایی و نرم افزار دیگسایلنت به کمک زبان برنامه نویسی پایتون</title_fa>
	<title>Design and development of a software module for optimal reconfiguration of distribution network in the context of GIS and DIgSILENT software using Python programming language</title>
	<subject_fa>برق و کامپیوتر</subject_fa>
	<subject></subject>
	<content_type_fa>كاربردي</content_type_fa>
	<content_type>Applicable</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;پیکربندی شبکه&#8204;های توزیع با تغییر ساختار شبکه&#8204;های توزیع از طریق باز وبست کلیدها و اتصال نقاط مانور به منظور بهبود شاخص&#8204;های شبکه توزیع مانند کاهش تلفات، تعادل ولتاژ و افزایش نفوذ منابع تولید پراکنده انجام میشود. با افزایش حضور منابع تولید پراکنده در شبکه&#8204;های توزیع، مسائل توسعه شهری، اضافه شدن بارهای نقطه ای، ایجاد شرایط بحرانی در شبکه توزیع، تعمیرات دوره ای شبکه و احداث پست جدید در شبکه توزیع ساختار شبکه&#8204;های توزیع نیازمند انعطاف پذیری بیشتری می&#8204;باشند تا بتوانند به این تغییرات پاسخ بدهند. در برخی از شرایط، تغییرات پیوسته بار و خروجی منابع تولید پراکنده سبب خارج شدن پارامترهای شبکه از محدوده استاندارد خود می&#8204;شوند، از این رو نیاز به پیکربندی بهینه شبکه از اهمیت بسیاری برخوردار می&#8204;باشد. پیکربندی دینامیکی شبکه تغییرات ساختار توپولوژیکی شبکه توزیع توسط بهره بردار توزیع با تغییرات وضعیت کلیدها به طور اتوماتیک یا دستی می&#8204;باشد. از این رو هدف این مقاله طراحی یک ماژول نرم افزاری کاربردی در بستر &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;GIS&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt; جهت تعیین پیکربندی بهینه شبکه در زمان&#8204;های دلخواه بهره برداران به منظور بهبود تلفات می&#8204;باشد. به منظور رسیدن به هدف ذکر شده در ابتدا اطلاعات موجود در &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;GIS&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt; توسط یک جعبه ابزار جدید استخراج شده است. سپس به کمک طراحی یک ماژول جدید، اطلاعات استخراج شده به نرم افزار &lt;/span&gt;&lt;/span&gt;&amp;nbsp;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;DIgSILENT&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;معرفی شده است. در گام بعدی، به کمک ماژول طراحی شده جدید، پیکربندی بهینه شبکه انجام شده است. در نهایت، کلیدهای تعیین شده جهت انجام بازارآیی توسط یک ماژول دیگر در &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;GIS&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt; قابل مشاهده می باشد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;The configuration of distribution networks is done by changing the structure of distribution networks through opening and closing switches and connecting maneuver points in order to improve the indicators of distribution network such as reducing losses, voltage balance, and increasing penetration of distributed generation sources. With the increasing presence of distributed generation sources in distribution networks, issues such as urban development, adding point loads, creating critical conditions in distribution network, periodic repairs of network and construction of new substation in distribution network, the structure of distribution networks need more flexibility to be able to respond to these changes. In some situations, continuous changes of load and output of distributed generation sources cause the network parameters to go out of their standard range, therefore, there is a need for optimal reconfiguration of network with great importance. Dynamic reconfiguration of network is the change of structural topology of distribution network by distribution operator with changing the status of switches automatically or manually. Therefore, the aim of this paper is to design a practical software module in GIS platform to determine the optimal configuration of network at desired times of operators for improving losses. To achieve this goal, the information available in GIS is extracted by a new toolbox. Then, with the help of designing a new module, the extracted information is converted and imported to DIgSILENT software. In the next step, with the help of the new designed module, the optimal configuration of network is done. Finally, the switches determined for reconfiguration are visible by another module in GIS&lt;span b=&quot;&quot; dir=&quot;RTL&quot; lang=&quot;FA&quot; nazanin=&quot;&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract>
	<keyword_fa>پیکربندی بهینه, شبکه توزیع, کاهش تلفات, شرایط بحرانی, ماژول کاربردی</keyword_fa>
	<keyword>Optimal reconfiguration, Loss reduction, GIS</keyword>
	<start_page>1</start_page>
	<end_page>9</end_page>
	<web_url>http://ieijqp.ir/browse.php?a_code=A-10-1184-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Saleh</first_name>
	<middle_name></middle_name>
	<last_name>Saeidi</last_name>
	<suffix></suffix>
	<first_name_fa>صالح</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سعیدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>saleh_s86@yahoo.com</email>
	<code>10031947532846007488</code>
	<orcid>10031947532846007488</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Ar.C., Islamic Azad University, Arak, Iran</affiliation>
	<affiliation_fa>گروه مهندسی برق، واحد اراک، دانشگاه آزاد اسلامی، اراک، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Ali Asghar</first_name>
	<middle_name></middle_name>
	<last_name>Ghadimi</last_name>
	<suffix></suffix>
	<first_name_fa>علی اصغر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>قدیمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>a-ghadimi@araku.ac.ir</email>
	<code>10031947532846007489</code>
	<orcid>10031947532846007489</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Electrical Engineering, Faculty of Engineering, Arak University, Arak 38156-8-8349, Iran</affiliation>
	<affiliation_fa>گروه مهندسی برق، دانشکده فنی و مهندسی، دانشگاه اراک، اراک، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Reza</first_name>
	<middle_name></middle_name>
	<last_name>Miveh</last_name>
	<suffix></suffix>
	<first_name_fa>محمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>میوه</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>miveh@tafreshu.ac.ir</email>
	<code>10031947532846007490</code>
	<orcid>10031947532846007490</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Tafresh University, Tafresh 39518-79611, Iran</affiliation>
	<affiliation_fa>دانشکده مهندسی برق، دانشگاه تفرش، تفرش، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
