<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Electric Industry Journal of Quality and Productivity</title>
<title_fa>نشریه کیفیت و بهره وری صنعت برق ایران</title_fa>
<short_title>ieijqp</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ieijqp.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2344</journal_id_issn>
<journal_id_issn_online>2717-1639</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61186/ieijqp</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1402</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2023</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<volume>12</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مکان‌یابی خطا در خط انتقال مبتنی بر امواج سیار و مورفولوژی ریاضی بدون نیاز به سیستم همزمان‌سازی و پارامترهای خط</title_fa>
	<title>Traveling wave - based transmission line fault location using maathematical morphology without synchronization system and line parameters</title>
	<subject_fa>برق و کامپیوتر</subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p style=&quot;font-style: normal; text-align: justify;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;مکان&amp;shy;یابی دقیق خطا در یک سیستم خط انتقال برای شرکت&amp;shy;های برق به منظور تشخیص سریع محل اختلال، بسیار اهمیت دارد&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt; استفاده از یک تکنیک مناسب برای مکان&amp;shy;یابی دقیق خطا، به طور موثر منجر به کاهش زمان بازیابی خطا و هزینه عملیات سیستم در طول تعمیر و نگهداری می شود. در نتیجه، قابلیت اطمینان و کیفیت تحویل برق بهبود و زیان اقتصادی ناشی از قطعی خطوط کاهش می&amp;shy;یابد&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color:black&quot;&gt; در این مقاله، یک روش دقیق مکان&amp;shy;یابی خطا مبتنی بر امواج سیار دو پایانه&amp;shy;ای برای خطوط انتقال پیشنهاد شده است. در این روش، بر اساس زمان رسیدن امواج سیار اول و دوم ناشی از خطای اتصال کوتاه که به صورت جداگانه در هر دو پایانه خط انتقال اندازه&amp;shy;گیری می&amp;shy;شوند، محل خطا و زمان وقوع آن تعیین می&amp;shy;شود. الگوریتم پیشنهادی به همگام&amp;shy;سازی داده&amp;shy;ها، پارامترهای خط انتقال و سرعت موج سیار که منبع خطا در روش&amp;shy;های مکان&amp;shy;یابی خطا مبتنی بر امواج سیار هستند، نیاز ندارد. مکان&amp;shy;یابی خطا مبتنی بر امواج سیار نیازمند اطلاعات دقیق و کامل از سیگنال&amp;shy;های جریان و ولتاژ ناشی از خطا است.&amp;nbsp; به منظور استخراج بهتر زمان رسیدن امواج سیار و تحلیل سیگنال&amp;shy;های گذرا ناشی از خطای اتصال کوتاه، فیلتر مورفولوژی ریاضی&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;MMF&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&amp;nbsp;بکارگرفته شده است.&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;خطاهای مختلفی در یک خط انتقال 400 کیلوولت&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;به طول 200 کیلومتر با استفاده از برنامه&lt;/span&gt;&lt;/span&gt; &lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;EMTP &lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;و &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;MATLAB&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;شبیه&amp;shy;سازی شده است. نتایج شبیه&amp;shy;سازی تأیید می&amp;shy;کنند که الگوریتم پیشنهادی مستقل از نوع و امپدانس خطا بوده و قادر است با دقت بالا مکان خطا روی خط انتقال را تعیین کند.&lt;/span&gt;&lt;/span&gt; &lt;span dir=&quot;LTR&quot; style=&quot;color:black&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;br&gt;
&amp;nbsp;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;span lang=&quot;EN&quot;&gt;&lt;span cambria=&quot;&quot;&gt;Accurate fault location in a transmission line system is very important for &lt;/span&gt;&lt;/span&gt;&lt;span cambria=&quot;&quot;&gt;electric utilities &lt;/span&gt;&lt;span lang=&quot;EN&quot;&gt;&lt;span cambria=&quot;&quot;&gt;in order to quickly diagnose the location of the fault. Using a suitable technique for accurate fault location effectively reduces the time of fault recovery and system operation cost during maintenance. As a result, the reliability and quality of electricity delivery is improved and the economic losses caused by line outages are reduced. &lt;/span&gt;&lt;/span&gt;&lt;span cambria=&quot;&quot;&gt;In this paper, an accurate two-terminal traveling wave-based fault location method for transmission lines is proposed.&lt;/span&gt; &lt;span lang=&quot;EN&quot;&gt;&lt;span cambria=&quot;&quot;&gt;In this method, based on the arrival time of the first and second traveling waves caused by the short circuit fault, which are measured separately at both terminals of the transmission line, fault location and fault inception time are determined&lt;/span&gt;&lt;/span&gt;&lt;span cambria=&quot;&quot;&gt;.&lt;/span&gt; &lt;span lang=&quot;EN&quot;&gt;&lt;span cambria=&quot;&quot;&gt;The proposed algorithm does not need to synchronize data, transmission line&lt;/span&gt;&lt;/span&gt; &lt;span cambria=&quot;&quot;&gt;&amp;nbsp;parameters&lt;/span&gt;&lt;span lang=&quot;EN&quot;&gt;&lt;span cambria=&quot;&quot;&gt;, and traveling wave speed, which are sources of error in traveling wave-based fault location methods&lt;/span&gt;&lt;/span&gt;&lt;span cambria=&quot;&quot;&gt;. &amp;nbsp;In order to better analyse fault-induced transient signals and detects the arrival time of travelling waves, mathematicl morphology filter (MMF) is used.&lt;/span&gt; &lt;span cambria=&quot;&quot;&gt;Several faults on a typical 400 kV, 200 km transmission line were simulated using EMTP &amp;nbsp;and MATLAB programs. The simulation results verified the proposed algorithm is able to accurately locate faults on transmission line&lt;/span&gt;&lt;span lang=&quot;EN&quot;&gt;&lt;span cambria=&quot;&quot;&gt;. Also, the proposed method is independent of fault conditions shch as fault impedance, fault type, fault inception time and fault location&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;.&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-family:&quot;Cambria&quot;,serif&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract>
	<keyword_fa>مکان‌یابی خطا, خطوط انتقال, امواج سیار, مورفولوژی ریاضی</keyword_fa>
	<keyword>Fault location, transmission lines, traveling wave, mathematicl morphology</keyword>
	<start_page>71</start_page>
	<end_page>81</end_page>
	<web_url>http://ieijqp.ir/browse.php?a_code=A-10-1513-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>moslem</first_name>
	<middle_name></middle_name>
	<last_name>salehi</last_name>
	<suffix></suffix>
	<first_name_fa>مسلم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صالحی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>salehi.mo@fe.lu.ac.ir</email>
	<code>4189139971</code>
	<orcid>10031947532846006393</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Technical and Vocational University (TVU)</affiliation>
	<affiliation_fa>دانشکده مهندسی برق- دانشگاه فنی و حرفه‌ای- تهران- ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>ali akbar</first_name>
	<middle_name></middle_name>
	<last_name>moti birjandi</last_name>
	<suffix></suffix>
	<first_name_fa>علی اکبر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مطیع بیرجندی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>motiebirjandi@srttu.edu</email>
	<code>09126200817</code>
	<orcid>10031947532846006394</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Shahid Rajaee Teacher Training University</affiliation>
	<affiliation_fa>دانشکده مهندسی برق - دانشگاه تربیت دبیر شهید رجایی - تهران- ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
