<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Electric Industry Journal of Quality and Productivity</title>
<title_fa>نشریه کیفیت و بهره وری صنعت برق ایران</title_fa>
<short_title>ieijqp</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ieijqp.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2344</journal_id_issn>
<journal_id_issn_online>2717-1639</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61186/ieijqp</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بهبود دقت پیش‌بینی زمان‌ خاموشی برنامه‌ریزی نشده شبکه‌ی توزیع برق با استفاده از مدل سری زمانی‌ ARIMAX (مطالعه موردی شبکه توزیع برق استان یزد)</title_fa>
	<title>Improving the accuracy of forecasting unplanned power extinction (outage) time of power distribution network using ARIMAX time series model (Case study: Yazd power distribution network)</title>
	<subject_fa>صنایع و مدیریت</subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;شبکه توزیع برق یک زنجیره تامین پر اهمیت است که ترکیبی از فرآیندهای گوناگون می&#8204;باشد. از آنجا که، برق کالایی به شدت فناپذیر است، بنابراین رویکردی جامع نسبت به زمان خاموشی&#8204;های برنامه&#8204;ریزی نشده، به منظور جلوگیری از هرگونه تلفات برق بسیار ارزشمند است. حوادث گوناگونی در شبکه&#8204;های توزیع برق ایجاد اختلال می&#8204;کنند که شبکه، بدون خط گرم قابل تعمیر و بازگشت به حالت اولیه می&#8204;باشد. پیش&#8204;بینی این حوادث و مدیریت آن&#8204;ها در کاهش زمان&#8204;های خاموشی برنامه&#8204;ریزی نشده می&#8204;تواند موثر باشد. هدف این مقاله، ارائه مدل پیش&#8204;بینی&amp;nbsp; مدت زمان خاموشی&#8204;های برنامه&#8204;ریزی نشده و انرژی به فروش نرفته بر اساس داده&#8204;های ثبت شده در سامانه 121، شبکه&#8204;ی شهری امور سه شرکت توزیع برق استان یزد است. نتیجه نهایی این تحقیق نشان&#8204; می&#8204;دهد که مدل&#8204;(های) &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;ARIMAX&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&amp;nbsp; نسبت به مدل(&#8204;های) &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;ARIMA&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&amp;nbsp; خطای کمتری را نشان داده و پیش&#8204;بینی بهتری را ارائه می&#8204;دهند. لذا استفاده متغیرهای برون&#8204;زا در پیش&#8204;بینی&#8204;ها و عدم اکتفا به نوسانات یک متغیر می&#8204;تواند نتایج بهتری در پیش&#8204;بینی&#8204;ها ارائه دهد. همچنین مدل به دست آمده نشان&#8204;می&#8204;دهد در تیرماه سال 1401 مدت زمان خاموشی بی&#8204;برنامه&#8204; قریب به ده ساعت در این شبکه و همچنین توان به فروش نرفته تقریبا 6 مگاوات ساعت خواهد بود.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;&lt;/strong&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;Electric power and power distribution are prominent infrastructures for economic development in any developing country like Iran. Also, the power distribution network is a very important supply chain that combines a variety of processes. Smart electrical energy distribution networks are one of the latest technologies in the world. The main goal of these networks is to provide reliable electricity, increase the reliability factor and network stability, and respond to the growing needs of customers with minimal damage to the environment, profit, and high efficiency. In the last three decades, the rapid evolution and prevalent adoption of information systems, distribution analysis tools, computational models, and more recently, the emergence of smart grid technologies have given utilities access to the data and tools required for improving these analyses and the possibility of increasing the efficiency of power distribution systems (by, for example, reducing losses and optimizing voltage profiles). Forecasting the future state of the network with the least error brings us closer to the smart network. Because electricity is a mortal product, a comprehensive approach to unplanned power extinction (outage) time is very valuable in preventing any power distribution losses. Various accidents disrupt (cause breakdowns in) the power distribution network, which can be repaired and restored without a hotline. One of the main reasons for customers&amp;#39; power outages is the blackouts in the distribution field, which are affected by technical and non-technical events in the electricity distribution networks. Forecasting these events and managing them can be effective in reducing unplanned power extinction (outage) time. The purpose of this article is to present a model for predicting the duration of unplanned power extinction (outage) and unsold energy based on the data recorded from 121 systems (controllers), the urban network of the three power distribution companies in Yazd province. The final result shows that the ARIMAX model(s) shows less error than the ARIMA model(s) and presents better prediction. Therefore, using exogenous variables in predictions and not being satisfied with the fluctuations of a variable can improve predictions. The model proposed for predicting unsold energy is ARIMAX(1,0,1)(0,0,0) considering the number of incidents and the time of unplanned outages as exogenous variables. The model also shows that in July 2022, the unplanned power extinction (outage) time of this network will be approximately ten hours and also the unsold power will be approximately 6 MWH. On the other hand, the community is without electricity and dissatisfaction has arisen, which lies in economic and social losses. Therefore, with this warning, managers should re-examine the factors of disruption and lack of electricity supply and think of measures to reduce these blackouts when planning for this month of the year&lt;/span&gt;&lt;/span&gt;</abstract>
	<keyword_fa>شبکه توزیع برق, پیش‌بینی, خاموشی برنامه‌ریزی نشده, سری زمانی, انرژی</keyword_fa>
	<keyword>Power distribution network, forecasting, unplanned blackouts (outage), time series, energy</keyword>
	<start_page>39</start_page>
	<end_page>47</end_page>
	<web_url>http://ieijqp.ir/browse.php?a_code=A-10-1472-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Elham</first_name>
	<middle_name></middle_name>
	<last_name>Fallah Baghmortini</last_name>
	<suffix></suffix>
	<first_name_fa>الهام</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فلاح باغمورتینی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>fallah9902314@stu.yazd.ac.ir</email>
	<code>4420749164</code>
	<orcid>10031947532846006064</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Yazd University</affiliation>
	<affiliation_fa>گروه مهندسی صنایع دانشگاه یزد - یزد- ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Motahareh</first_name>
	<middle_name></middle_name>
	<last_name>Karami</last_name>
	<suffix></suffix>
	<first_name_fa>مطهره</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کرمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mthkarami1@gmail.com</email>
	<code>0640458459</code>
	<orcid>10031947532846006065</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Yazd University</affiliation>
	<affiliation_fa>گروه مهندسی صنایع دانشگاه یزد - یزد- ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Davood</first_name>
	<middle_name></middle_name>
	<last_name>Shishebori</last_name>
	<suffix></suffix>
	<first_name_fa>داود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شیشه بری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>shishebori@yazd.ac.ir</email>
	<code>4432459174</code>
	<orcid>10031947532846006066</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Yazd University</affiliation>
	<affiliation_fa>گروه مهندسی صنایع دانشگاه یزد - یزد- ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
