<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Electric Industry Journal of Quality and Productivity</title>
<title_fa>نشریه کیفیت و بهره وری صنعت برق ایران</title_fa>
<short_title>ieijqp</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ieijqp.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2344</journal_id_issn>
<journal_id_issn_online>2717-1639</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61186/ieijqp</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>2</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>شبیه سازی و تحلیل بکارگیری محدودساز بین خطی در پستهای فشار قوی به منظور کاهش جریان اتصال کوتاه، افت ولتاژ و بهبود پایداری مولدهای مقیاس کوچک    – مطالعه موردی: پست  منطقه ویژه اقتصادی بندر امیرآباد</title_fa>
	<title>Simulation and Analysis of Using Interline bridge‐type fault current limiter in High Voltage Substations for Reducing  Short Circuit Current, Voltage Drop and Improve the Stability of Distribution Generation; Case Study: Substation in Special Economic Zone of AMIRABAD Port</title>
	<subject_fa>برق و کامپیوتر</subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>امروزه با نوجه به گسنرش و توسعه شبکه انتقال انرژی و بکارگیری مولدهای مقیاس کوچک و افزایش ظرفیت مراکز تولید، سطح اتصال کوتاه شبکه افزایش قابل ملاحظه ای پیدا کرده است. افزایش سطح اتصال کوتاه مشکلات متعددی را برای تجهیزات شبکه ایجاد می نماید. لذا می بایست به طریقی بتوان شدت آن را کاهش تا آثار آن تضعیف شود که یکی از این روشها بکارگیری محدودساز جریان خطا می باشد. در این مقاله به جهت انجام مطالعه موردی، اثرات بکارگیری محدود کننده جریان خطای بین خطی، برای کاهش جریان اتصال کوتاه و بهبود پایداری مولدهای مقیاس کوچک متصله در یک پست نمونه مورد بررسی قرار می گیرد. پست 20/63/230 کیلوولت منطقه ویژه اقتصادی بندر امیرآباد شامل چندین فیدر خروجی برای اتصال بارها و چهار مولد مقیاس کوچک به شین مشترک 20 کیلوولت می باشد. در این پست اتصال مولدهای مقیاس کوچک برای تامین توان مورد نیاز مصرف کنندگان، باعث افزایش جریان اتصال کوتاه به مقداری بیشتر از ظرفیت نامی تجهیزات منصوبه شده و بروز اتصال کوتاه در یکی از فیدرها، منجر به کمبود ولتاژ در باس مشترک و ناپایداری مولدها گردیده است. این امر باعث خروج مولدهای مقیاس کوچک و بارهای حساس متصل به فیدرهای موازی و کاهش قابلیت اطمینان شده است. &amp;nbsp;&amp;nbsp;&lt;br&gt;
در این مقاله به جهت کاهش جریان اتصال و جلوگیری از خروج مولدهای مقیاس کوچک و بارهای حساس در این پست، محدودساز بین خطی پیشنهاد گردیده است. این محدود کننده از چندین مدار یکسوساز و یک مقاومت محدود ساز مشترک تشکیل شده است که در صورت بروز اتصال کوتاه در هر یک از فیدرها، با قرار دادن مقاومت محدود ساز مشترک در مسیر جریان خطا، دامنه جریان و متعاقبا دامنه افت ولتاژ نیز محدود می گردد. برای اثبات کارآئی ساختار پیشنهادی در رفع مشکلات شبکه مورد مطالعه، اجزاء پست در نرم افزار &lt;span dir=&quot;LTR&quot;&gt;PSCAD/EMTDC&lt;/span&gt; مورد شبیه سازی و بررسی قرار گرفته است. نتایج شبیه سازی ها نشان می دهد که محدود کننده پیشنهادی به طور موثری باعث کاهش جریان خطا و کاهش افت ولتاژ و همچنین بهبود پایداری مولد های مقیاس کوچک می گردد.</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;line-height:normal&quot;&gt;Due to the expansion and development of the distribution networks and the use of distributed generators (DGs), the level of short-circuit current has increased significantly. Increasing the short circuit current level provides several challenges for network equipment.&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:normal&quot;&gt;&amp;nbsp;In this paper, the effects of using the inter-line fault current limiter (IFCL) to reduce the short-circuit current and improve the stability of DGs installed in the 230/63/20 kV AMIRABAD substation as a case study are investigated. It includes several output feeders for connecting loads and four DGs to a common coupling point 20 kV bus. In this substation, the connection of DGs to supply the power required by consumers, has increased the short-circuit current to a greater amount than the nominal capacity of the equipment. Also the occurrence of short-circuit in one of the feeders has led to voltage sag in the common bus and the instability of the generators. This has caused the exit of generators and sensitive loads connected to parallel feeders and finally reduce the reliability. IFCL consists of several rectifier bridge circuits and a common limiting resistor. It inserts the common limiting resistor in fault path for limiting the fault current level and consequently the voltage drop in the case of short circuit of the feeders. To prove the efficiency of the proposed structure for solving the problems of the studied network, the substation components in PSCAD / EMTDC software are simulated. The simulation results show that the proposed IFCL effectively reduces the fault current and voltage drop, as well as improves the stability of DGs.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract>
	<keyword_fa>جریان اتصال کوتاه, کمبود ولتاژ, محدود ساز جریان خطا بین خطی, مولد مقیاس کوچک</keyword_fa>
	<keyword>short circuit current,voltage sag,Interline bridge‐type fault current limiter,distributed generator</keyword>
	<start_page>61</start_page>
	<end_page>71</end_page>
	<web_url>http://ieijqp.ir/browse.php?a_code=A-10-1218-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>seyed esmaeel</first_name>
	<middle_name></middle_name>
	<last_name>naghibi</last_name>
	<suffix></suffix>
	<first_name_fa>سیداسماعیل</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نقیبی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>2180405979</code>
	<orcid>10031947532846005974</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Faculty of Electrical and Computer Engineering, Babol Noshirvani University of Technology, Babol, Iran</affiliation>
	<affiliation_fa>دانشکده مهندسی برق و کامپیوتر- دانشگاه صنعتی نوشیروانی بابل-  ایران و شرکت برق منطقه ای مازندران و گلستان- ساری-ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>mohammad</first_name>
	<middle_name></middle_name>
	<last_name>mirzaie</last_name>
	<suffix></suffix>
	<first_name_fa>محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>میرزایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mirzaie@nit.ac.ir</email>
	<code>2161643665</code>
	<orcid>10031947532846005975</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Faculty of Electrical and Computer Engineering, Babol Noshirvani University of Technology, Babol, Iran</affiliation>
	<affiliation_fa>دانشکده مهندسی برق و کامپیوتر- دانشگاه صنعتی نوشیروانی بابل- بابل- ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>taghi</first_name>
	<middle_name></middle_name>
	<last_name>Barforoushi</last_name>
	<suffix></suffix>
	<first_name_fa>تقی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بارفروشی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>barforoshi@nit.ac.ir</email>
	<code>2061267238</code>
	<orcid>10031947532846005976</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Faculty of Electrical and Computer Engineering, Babol Noshirvani University of Technology, Babol, Iran</affiliation>
	<affiliation_fa>دانشکده مهندسی برق و کامپیوتر- دانشگاه صنعتی نوشیروانی بابل- بابل- ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
