<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Electric Industry Journal of Quality and Productivity</title>
<title_fa>نشریه کیفیت و بهره وری صنعت برق ایران</title_fa>
<short_title>ieijqp</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ieijqp.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2344</journal_id_issn>
<journal_id_issn_online>2717-1639</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61186/ieijqp</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تشخیص محل تخلیه جزئی در خطوط توزیع فشار متوسط با هادی روکش دار</title_fa>
	<title>Detection of partial discharge in covered conductor medium voltage distribution lines</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span dir=&quot;RTL&quot;&gt;این مقاله روشی را جهت تشخیص محل تخلیه جزئی در خطوط هادی روکش دار فشار متوسط ارائه می&#8204;دهد تخلیه جزئی یکی از عیوب رایج در هادی&#8204;های روکش&#8204;دار می&#8204;باشد که در صورت وجود طولانی مدت حتی می&#8204;تواند منجر به عملکرد رله تشخیص خطای اتصال کوتاه گردد. روش پیشنهادی ارائه شده در این مقاله، پالس &lt;/span&gt;PD&lt;span dir=&quot;RTL&quot;&gt; دریافت شده در انتهای خط را به کمک روش حداکثر همبستگی سیگنال&#8204;ها مورد تحلیل می&#8204;دهد و محل وقوع تخلیه جزئی با دقت بالایی تشخیص می&#8204;دهد. &amp;nbsp;جهت مدلسازی خط سه فاز &lt;/span&gt;CC&lt;span dir=&quot;RTL&quot;&gt; در نرم&#8204;افزار &lt;/span&gt;EMTP&lt;span dir=&quot;RTL&quot;&gt; ، روابط تحلیلی مربوط به امپدانس&#8204;ها و خازن&#8204;های توالی&#8204;های صفر، مثبت&lt;/span&gt; &lt;span dir=&quot;RTL&quot;&gt;و منفی این نوع خط برای اولین بار ارائه شده است&amp;nbsp; و سپس به کمک روابط بدست آمده مدل مربوط به وقوع تخلیه جزئی در خطوط هادی روکش دار سه فاز &amp;nbsp;استخراج شده است. در ادامه به کمک روش پیشنهادی محل تقریبی وقوع تخلیه&#8204;های جزئی ناشی از تماس درختان یا عوامل دیگر با هادی روکش&#8204;دار &amp;nbsp;تعیین می&#8204;شود تا از طریق بازدیدهای بصری و رفع&lt;/span&gt; &lt;span dir=&quot;RTL&quot;&gt;مانع موجود بر هادی برقدار، از پیشروی رخداد تخلیه&#8204;های جزئی و قطعی برق مشترکین جلوگیری&lt;/span&gt; &lt;span dir=&quot;RTL&quot;&gt;شود. روش پیشنهادی در یک شبکه نمونه توزیع اعمال شده است ونتایج مطلوبی بدست آمده است. محل خطا با در نظر گرفتن حالت&#8204;های مختلف برای وقوع &lt;/span&gt;PD&lt;span dir=&quot;RTL&quot;&gt; با دقت بسیار مناسبی تشخیص داده شده است.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;This paper presents a method for detecting the location of partial discharge in medium voltage covered conductor (CC) lines. The use of CCs is increasing day by day due to higher reliability, less susceptibility to climate change, and fewer short circuit faults than overhead lines.&amp;nbsp; CCs are commonly used in forests.&amp;nbsp; The lack of rapid failure detection of protection relays when the tree falls on the CC is one of its most important disadvantages. Scratching of CC insulation due to a tree falling on it usually leads to partial discharge (PD), which can lead to short circuit faults in the long run. Because the CC may be installed in an impassable path, it is difficult to detect a tree falling on the CC or the growing foliage colliding with the CC, and if not done promptly, it can lead to a short circuit fault. In this paper, for the first time, while obtaining a three-phase CC model, the falling of a tree on CC is simulated by applying a PD pulse source at the desired location. The proposed method is that first the PD signal is applied at the location of the electrical posts and the waveform obtained at the end of the line is stored and then their FFT is calculated as reference signals. To find the location of an unknown location PD, the signal obtained at the end of the line is saved after eliminating its main component of frequency and noise. Afterward, its FFT is calculated. Then, using the method of maximum correlation of signals, the nearest electric pole to the location of PD is determined. The proposed method was applied in different cases in a sample system, and satisfactory results were obtained.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;span style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>تخلیه جزئی, تشخیص محل , روش حداکثر همبستگی, ظرفیت خازنی فاز به زمین, مدلسازی هادی روکش دار, نرم‌افزار EMTP, هادی روکش‌دار.</keyword_fa>
	<keyword>Covered Conductor, Partial Discharge, Location detection, Maximum Correlation Method, Phase to Ground Capacitor, Covered Conductor Modeling, EMTP.</keyword>
	<start_page>82</start_page>
	<end_page>96</end_page>
	<web_url>http://ieijqp.ir/browse.php?a_code=A-10-1202-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohammad Ali</first_name>
	<middle_name></middle_name>
	<last_name>Yavari</last_name>
	<suffix></suffix>
	<first_name_fa>محمدعلی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یاوری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ayavari.m@gmail.com</email>
	<code>4431891161</code>
	<orcid>10031947532846005528</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Yazd University, Yazd, Iran, </affiliation>
	<affiliation_fa>دانشکده مهندسی برق-دانشگاه یزد-یزد-ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Davoud</first_name>
	<middle_name></middle_name>
	<last_name>Abootorabi Zarchi</last_name>
	<suffix></suffix>
	<first_name_fa>داود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ابوترابی زارچی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>d.abootorabi@yazd.ac.ir</email>
	<code>4431891161</code>
	<orcid>10031947532846005529</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Electrical Engineering, Yazd University, Yazd, Iran, </affiliation>
	<affiliation_fa>دانشکده مهندسی برق-دانشگاه یزد-یزد-ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Alireza</first_name>
	<middle_name></middle_name>
	<last_name>Sedighi Anaraki</last_name>
	<suffix></suffix>
	<first_name_fa>علیرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صدیقی انارکی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>sedighi@yazd.ac.ir</email>
	<code>1249462533</code>
	<orcid>10031947532846005530</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Yazd University, Yazd, Iran, </affiliation>
	<affiliation_fa>دانشکده مهندسی برق-دانشگاه یزد-یزد-ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
