<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Electric Industry Journal of Quality and Productivity</title>
<title_fa>نشریه کیفیت و بهره وری صنعت برق ایران</title_fa>
<short_title>ieijqp</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ieijqp.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2344</journal_id_issn>
<journal_id_issn_online>2717-1639</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61186/ieijqp</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تشخیص عیب و کنترل تحمل پذیر خطا در مبدل پشت به پشت DFIG</title_fa>
	<title>Fault Diagnostic and Fault Tolerant Control of DFIG Back to Back Converter</title>
	<subject_fa>برق و کامپیوتر</subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div&gt;&lt;span dir=&quot;RTL&quot;&gt;پایش وضعیت، عیب&amp;shy;یابی و کنترل تحمل&amp;shy;پذیر خطای توربین بادی موجب افزایش قابلیت اطمینان و در دسترس بودن توربین می&amp;shy;شود. نرخ عیب مدار باز سوئیچ &lt;/span&gt;IGBT&lt;span dir=&quot;RTL&quot;&gt; مبدل در مقایسه با نرخ کل عیوب در توربین بادی قابل توجه است. در این مقاله به کنترل تحمل&amp;shy;پذیر خطای مدار باز &lt;/span&gt;IGBT&lt;span dir=&quot;RTL&quot;&gt; در مبدل&amp;shy;های پشت به پشت ژنراتور &lt;/span&gt;DFIG&lt;span dir=&quot;RTL&quot;&gt; پرداخته شده است. در ساختار پیشنهادی ابتدا تشخیص عیب سوئیچ مبدل با استفاده از یک روش سریع و عددی انجام می&amp;shy;شود و سپس کنترل تحمل&amp;shy;پذیر خطا به منظور جبران&amp;shy;سازی نقصان پیش آمده فعال می&amp;shy;شود، در این روش ساق معیوب با باز شدن گیت هر دو &lt;/span&gt;IGBT&lt;span dir=&quot;RTL&quot;&gt; در یک ساق توسط کنترل&amp;shy;کننده، کنار رفته و یکی از ساق&amp;shy;ها به عنوان ساق مشترک بین دو مبدل سمت شبکه و سمت روتور قرار می&amp;shy;گیرد. ساختار پیشنهادی ارزان قیمت است و کنترل تحمل پذیر خطا در آن با حداقل سخت&amp;shy;افزار اضافه عمل می&amp;shy;کند. برای ارزیابی ساختار پیشنهادی از یک شبیه&amp;shy;ساز نرم&amp;shy;افزاری توربین 5/2 مگاوات بر اساس داده واقعی، استفاده شده است. شبیه&amp;shy;سازی&amp;shy;ها نشان داد که روش پیشنهادی در تشخیص عیوب، موثر و مقاوم است و به خوبی توانسته است جبران&amp;shy;سازی خطای سوئیچ را برای ساختن جریان&amp;shy;های سه فاز خروجی انجام دهد، مقایسه شاخص&amp;shy;های عددی، توانایی روش پیشنهادی را مشخص کرده است. &lt;/span&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;One of the most common types of wind turbines (WTs) is the Doubly-Fed Induction Generator (DFIG) with a back-to-back converter. The power converter with an Insulated Gate Bipolar Transistor (IGBT) switch is essential equipment for power regulation and grid connection in WTs.&lt;b&gt; &lt;/b&gt;The converter IGBT open-circuit causes a drawback in output current and as a result, the production performance of the turbine is reduced. Condition Monitoring (CM), Fault Diagnostic (FD), and Fault-Tolerant Control (FTC) of a WT increase the reliability and availability of the turbine and are typical methods to reduce energy production costs and WT downtime. The IGBT switch&amp;rsquo;s open-circuit failure rate is significant compared to the overall fault rate in WTs. This paper discusses IGBT open-circuit FTC in back-to-back DFIG converters. In the proposed structure, the converter switch fault is first diagnosed using a fast and numerical method. &lt;/span&gt;&lt;span lang=&quot;EN&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;In the first part, a method based on normalized phase currents, the absolute of the phase currents, and an adaptive threshold is used. &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;line-height:115%&quot;&gt;The FTC system can be divided into two classes of redundancy and non-redundancy or into active and inactive classes. &lt;/span&gt;&lt;span lang=&quot;EN&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;In this article, the proposed method is active and &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;line-height:115%&quot;&gt;non-redundancy&lt;/span&gt;&lt;span lang=&quot;EN&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;.&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;line-height:115%&quot;&gt;In the second step, the FTC process is activated to compensate for the system degradation. In this method, the faulty leg is removed with the gate opening of both IGBTs in one leg by the controller, and one of the legs is positioned as a common leg between the two grid side and rotor side converters. &lt;/span&gt;&lt;span lang=&quot;EN&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;The conventional method in this structure is to use Pulse Width Modulation (PWM) with a zero sequence signal.&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;EN&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;The novelty of the paper is the use of the proposed SVM vector control.&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;line-height:115%&quot;&gt;The proposed structure is inexpensive. Furthermore, the fault diagnostic structure operates without additional sensors and the FTC structure operates with minimal hardware. To evaluate the proposed structure, a 2.5 MW turbine software simulator based on real data is used. The simulations show that the proposed method is effective and robust in FD and FTC and that &lt;/span&gt;&lt;span lang=&quot;EN&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;the proposed method is successful in detecting multiple defects of the grid-side and rotor-side converters, as well as the defects of one leg.&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;line-height:115%&quot;&gt;The proposed method can compensate for the open switch fault to construct three-phase output currents by comparing the numerical parameters. The ability of the proposed method is specified.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>توربین بادی, DFIG, تشخیص عیب, کنترل تحمل‌پذیر خطا, مبدل پشت به پشت, توپولوژی بدون افزونه</keyword_fa>
	<keyword>Wind Turbine, DFIG, Fault Detection, Fault Tolerant Control, Back to Back Converter, Non-Redundant Topology</keyword>
	<start_page>126</start_page>
	<end_page>138</end_page>
	<web_url>http://ieijqp.ir/browse.php?a_code=A-10-1375-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mehrnoosh</first_name>
	<middle_name></middle_name>
	<last_name>Kamarzarrin</last_name>
	<suffix></suffix>
	<first_name_fa>مهرنوش</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کمرزرین</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>kamarzarrin.mehrnoosh@sru.ac.ir</email>
	<code>4160157671</code>
	<orcid>10031947532846005499</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Faculty of Electrical Engineering, Shahid Rajaee Teacher Training University, Tehran- Iran</affiliation>
	<affiliation_fa>دانشکده مهندسی برق- دانشگاه تربیت دبیر شهید رجایی- تهران- ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Hossein</first_name>
	<middle_name></middle_name>
	<last_name>Refan</last_name>
	<suffix></suffix>
	<first_name_fa>محمد حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رفان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>refan@sru.ac.ir</email>
	<code>2371774571</code>
	<orcid>10031947532846005500</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Faculty of Electrical Engineering, Shahid Rajaee Teacher Training University, Tehran- Iran</affiliation>
	<affiliation_fa>دانشکده مهندسی برق- دانشگاه تربیت دبیر شهید رجایی- تهران- ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Parviz</first_name>
	<middle_name></middle_name>
	<last_name>Amiri</last_name>
	<suffix></suffix>
	<first_name_fa>پرویز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>امیری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>pamiri@sru.ac.ir</email>
	<code>5899588500</code>
	<orcid>10031947532846005501</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Faculty of Electrical Engineering, Shahid Rajaee Teacher Training University, Tehran- Iran</affiliation>
	<affiliation_fa>دانشکده مهندسی برق- دانشگاه تربیت دبیر شهید رجایی- تهران- ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
