<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Electric Industry Journal of Quality and Productivity</title>
<title_fa>نشریه کیفیت و بهره وری صنعت برق ایران</title_fa>
<short_title>ieijqp</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ieijqp.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2344</journal_id_issn>
<journal_id_issn_online>2717-1639</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61186/ieijqp</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1400</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2021</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<volume>10</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بازیابی بهینه سیستم‌های توزیع فعال با هدف بهبود تاب‌آوری و با در نظر گرفتن عدم قطعیت منابع تجدیدپذیر</title_fa>
	<title>Optimal Restoration of Active Distribution Systems for Enhancing Resilience Considering the Uncertainty of Renewable Sources</title>
	<subject_fa>برق و کامپیوتر</subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;span dir=&quot;RTL&quot;&gt;هدف شبکه&#8204;های هوشمند در سراسر جهان، تأمین برق قابل اطمینان و تاب&#8204;آور به مشترکین می&#8204;باشد. در اتفاقات بزرگ ناشی از حوادث طبیعی، منابع تولید پراکنده در تغذیه قابل اطمینان و تاب&#8204;آور بارهای شبکه نقش کلیدی را بازی می&#8204;کنند. &lt;/span&gt;&lt;a name=&quot;_Hlk60746495&quot;&gt;&lt;span dir=&quot;RTL&quot;&gt;تاب&#8204;آوری&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt; سیستم&#8204;های قدرت را می توان به عنوان توانایی سیستم در آماده&#8204;سازی و برنامه&#8204;ریزی برای جذب آسیب و تطبیق/ بازیابی به منظور جلوگیری از تأثیرات حوادث مشابه در آینده تعریف کرد.&lt;/span&gt;&lt;/a&gt;&lt;span dir=&quot;RTL&quot;&gt; بنابراین، تاب آوری یک سیستم قدرت بطور خلاصه به سه مشخصه پیشگیری&lt;/span&gt;&lt;a href=&quot;#_ftn1&quot; name=&quot;_ftnref1&quot; title=&quot;&quot;&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span dir=&quot;LTR&quot;&gt;[1]&lt;/span&gt;&lt;/span&gt;&lt;/a&gt;&lt;span dir=&quot;RTL&quot;&gt;، قابلیت تداوم برق رسانی&lt;/span&gt;&lt;a href=&quot;#_ftn2&quot; name=&quot;_ftnref2&quot; title=&quot;&quot;&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span dir=&quot;LTR&quot;&gt;[2]&lt;/span&gt;&lt;/span&gt;&lt;/a&gt; &lt;span dir=&quot;RTL&quot;&gt;&amp;nbsp;و بازیابی&lt;/span&gt;&lt;a href=&quot;#_ftn3&quot; name=&quot;_ftnref3&quot; title=&quot;&quot;&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span dir=&quot;LTR&quot;&gt;[3]&lt;/span&gt;&lt;/span&gt;&lt;/a&gt;&lt;span dir=&quot;RTL&quot;&gt; نسبت داده می&#8204;شود. بهبود در هر یک یا تمام این سه مشخصه، تاب آوری کل سیستم را بهبود می&#8204;دهد. در این مقاله، یک الگوریتم بازیابی بهبود یافته در سیستم&#8204;های توزیع، با حضور منابع تولید پراکنده&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt; تجدیدپذیر و قابل برنامه&#8204;ریزی&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt; برای افزایش قابلیت تداوم تغذیه بارهای قطع شده ناشی از حوادث شدید همانند حوادث طبیعی ارائه می&#8204;شود. در مدل ارائه شده، یک استراتژی بهینه برای بازیابی حداکثر بارها با مینیمم عملکردهای کلیدزنی و حداکثر بازیابی بار تحت شرایط خطا پیشنهاد می&#8204;شود. در روش پیشنهادی، از الگوریتم ژنتیک به عنوان یک الگوریتم قدرتمند در بهینه سازی استفاده شده و چگونگی پیاده سازی و حل مدل پیشنهادی توسط الگوریتم ژنتیک معرفی می&#8204;گردد. کارایی روش پیشنهادی بر روی شبکه تست 33 باس &lt;/span&gt;IEEE&lt;span dir=&quot;RTL&quot;&gt; بررسی و نتایج حاصل تحلیل شده است.&lt;/span&gt;
&lt;div&gt;&amp;nbsp;
&lt;hr align=&quot;left&quot; size=&quot;1&quot; width=&quot;33%&quot; &gt;
&lt;div id=&quot;ftn1&quot;&gt;&lt;a href=&quot;#_ftnref1&quot; name=&quot;_ftn1&quot; title=&quot;&quot;&gt;[1]&lt;/a&gt; - prevention&lt;/div&gt;

&lt;div id=&quot;ftn2&quot;&gt;&lt;a href=&quot;#_ftnref2&quot; name=&quot;_ftn2&quot; title=&quot;&quot;&gt;[2]&lt;/a&gt; - survivability&lt;/div&gt;

&lt;div id=&quot;ftn3&quot;&gt;&lt;a href=&quot;#_ftnref3&quot; name=&quot;_ftn3&quot; title=&quot;&quot;&gt;[3]&lt;/a&gt; - recovery&lt;/div&gt;
&lt;/div&gt;</abstract_fa>
	<abstract>Smart grids all over the world aim at providing reliable and resilient power to customers. During major contingencies of large-scale natural disasters, Distributed Generations (DGs) play a key role in delivering a resilient and reliable supply of loads. Major natural disasters such as floods and hurricanes often cause lengthy interruptions in electricity distribution systems and degrade the level of service to end-users.&amp;nbsp;The utilities have mainly focused on restoring the distribution system since the power grid is &lt;a name=&quot;OLE_LINK7&quot;&gt;susceptible &lt;/a&gt;to natural disasters. A resilient system&amp;#39;s primary purpose is to allow the restoration of out-of-service loads as soon as possible after an extreme event.&amp;nbsp;The resilience of a power system can be defined as &amp;ldquo;the ability of the system to prepare and plan for absorbing the damage and adapting/recovering in order to prevent the impacts of similar events in the future&amp;rdquo;. Therefore, the resilience of a power system is briefly attributed to three aspects of prevention, survivability, and recovery.&amp;nbsp; Improvements in any or all of these features can enhance the overall resilience of the power system. This paper presents a self-healing restoration algorithm for power distribution systems exposed to extreme natural disasters. &lt;a name=&quot;OLE_LINK1&quot;&gt;Indeed&lt;/a&gt;, an improved restoration algorithm in distribution systems in the presence of renewable and dispatchable DGs is proposed for enhancing the survivability of out-of-service loads due to extreme events, like natural disasters.&lt;a name=&quot;OLE_LINK2&quot;&gt; The algorithm can analyze the effects of multiple faults, which arise due to a low-probability, high-impact event like a natural disaster. &lt;/a&gt;In the presented method, an optimal strategy is introduced to restore maximum loads with minimum switching operations and maximum load restoration under fault conditions. In order to consider uncertain parameters, a stochastic scenario-based approach is considered and the expected values as objectives are minimized to consider the effect of all scenarios. In the proposed method, the Genetic Algorithm (GA) is utilized as a powerful algorithm in optimization and how to implement and solve the proposed model by the GA is introduced. An evaluation of the proposed approach is conducted through a typical case study. A modified IEEE 33-node system is considered for this reason. The simulated results indicate that in the presence of microgrids and an automated switching-based distribution system, the system&amp;#39;s resilience is improved significantly.&amp;nbsp;However, the present study did not address microgrids&amp;#39; dynamic response. In the event of extreme natural disasters, utilities can use the proposed algorithm to improve the recovery of out-of-service loads.</abstract>
	<keyword_fa>تاب‌آوری, بازیابی بهینه, منابع تولید پراکنده, الگوریتم ژنتیک, تولید سناریو, عدم قطعیت</keyword_fa>
	<keyword>Resiliency, Optimal Restoration, Distributed Generations, Genetic Algorithm, Scenario Generation, Uncertainty</keyword>
	<start_page>97</start_page>
	<end_page>108</end_page>
	<web_url>http://ieijqp.ir/browse.php?a_code=A-10-1356-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Abouzar</first_name>
	<middle_name></middle_name>
	<last_name>Samimi</last_name>
	<suffix></suffix>
	<first_name_fa>ابوذر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صمیمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>abouzarsamimi@alumni.iust.ac.ir</email>
	<code>3961866562</code>
	<orcid>10031947532846004951</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Electrical Engineering, Arak University of Technology, Arak, Iran</affiliation>
	<affiliation_fa>دانشکده مهندسی برق- دانشگاه صنعتی اراک - اراک- ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mehdi</first_name>
	<middle_name></middle_name>
	<last_name>Nikzad</last_name>
	<suffix></suffix>
	<first_name_fa>مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نیکزاد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Mehdi.Nikzad@yahoo.com</email>
	<code>4132232425</code>
	<orcid>10031947532846004952</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Islamshahr Branch, Islamic Azad University, Tehran, Iran</affiliation>
	<affiliation_fa>دانشکده مهندسی برق- دانشگاه آزاد اسلامی واحد اسلامشهر - تهران- ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
