<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Electric Industry Journal of Quality and Productivity</title>
<title_fa>نشریه کیفیت و بهره وری صنعت برق ایران</title_fa>
<short_title>ieijqp</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ieijqp.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2344</journal_id_issn>
<journal_id_issn_online>2717-1639</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61186/ieijqp</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1398</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2019</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>8</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه اثر دو روش کنترل مبتنی بر همواری برای STATCOM در بهبود پایداری شبکه شامل مزارع بادی مبتنی بر DFIG</title_fa>
	<title>Comparison of the effects of two flatness based control methods for STATCOM on improving stability in power systems including DFIG based wind farms</title>
	<subject_fa>برق و کامپیوتر</subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;span dir=&quot;RTL&quot;&gt;شبکه&amp;shy;های قدرت، سیستم&amp;shy;های پیچیده به&amp;shy;هم پیوسته و غیرخطی هستند و هنگامی&amp;shy;که تحت نفوذ منابع بادی قرار می&amp;shy;گیرند، این مسئله شدیدتر خواهدبود. جبران&amp;shy;سازهای سنکرون استاتیکی&lt;/span&gt;&lt;sup&gt;&lt;span dir=&quot;RTL&quot;&gt;1&lt;/span&gt;&lt;/sup&gt; (STATCOM)&lt;span dir=&quot;RTL&quot;&gt; جهت بهبود تنظیم ولتاژ و برآورده نمودن کدهای شبکه، در سیستم&amp;shy;های قدرت، شامل مزارع بادی مبتنی بر ژنراتور القایی تغذیه دوگانه&lt;/span&gt;&lt;sup&gt;&lt;span dir=&quot;RTL&quot;&gt;2&lt;/span&gt;&lt;/sup&gt;&lt;span dir=&quot;RTL&quot;&gt; (&lt;/span&gt;DFIG&lt;span dir=&quot;RTL&quot;&gt;) مورد استفاده قرار می&amp;shy;گیرند.علی&amp;shy;رغم ماهیت غیرخطی &lt;/span&gt;STATCOM&lt;span dir=&quot;RTL&quot;&gt;، روش کنترلی مرسوم در آن&amp;shy;ها، براساس کنترل&amp;shy;کننده&amp;shy;های خطی &lt;/span&gt;PI&lt;span dir=&quot;RTL&quot;&gt; با ضرایب ثابت است که این ضرایب تضمینی برای عملکرد بهینه &lt;/span&gt;STATCOM&lt;span dir=&quot;RTL&quot;&gt; نمی&amp;shy;باشند. در این مقاله مقایسه&amp;shy;ای میان دو روش کنترلی غیرخطی مبتنی بر همواری دیفرانسیلی برای جبران&amp;shy;ساز سنکرون استاتیکی در شبکه 9 باس &lt;/span&gt;WSCC&lt;span dir=&quot;RTL&quot;&gt; شامل مزارع بادی مبتنی بر &lt;/span&gt;DFIG&lt;span dir=&quot;RTL&quot;&gt; انجام گرفته و نتایج شبیه&amp;shy;سازی عملکرد موثر هر دو روش را در مقایسه با روش کنترل خطی مرسوم نشان می&amp;shy;دهد.&lt;/span&gt;</abstract_fa>
	<abstract>Power grids are complex, interconnected and nonlinear systems, and this will be more severe when they are subjected to high wind resources penetration. Static synchronous compensators (STATCOM) are used to improve voltage regulation and to meet grid codes in power systems, including doubly fed induction generators (DFIG) based wind farms. Despite the nonlinear nature of STATCOM, the conventional control method in them is based on linear PI controllers with constant gains, which they cannot guarantee the optimal performance for STATCOM. In this paper, a comparison has been performed between two nonlinear control methods based on differential flatness theory for static synchronous compensators in the WSCC system includes DFIG based wind farms and simulation results demonstrate the effective performance of both methods in comparison with the conventional linear control method.&lt;br&gt;
&amp;nbsp;</abstract>
	<keyword_fa>جبران‌ساز سنکرون استاتیکی, قابلیت گذر از کمبود ولتاژ, کنترل مبتنی بر همواری, تئوری خطی سازی پسخورد, کنترل تطبیق‌پذیر مبتنی بر همواری</keyword_fa>
	<keyword>Static synchronous compensator, Low Voltage Ride through, Flatness based feedback linearization control, Flatness based adaptive control</keyword>
	<start_page>72</start_page>
	<end_page>81</end_page>
	<web_url>http://ieijqp.ir/browse.php?a_code=A-10-788-3&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Hamid</first_name>
	<middle_name></middle_name>
	<last_name>Ghaedi</last_name>
	<suffix></suffix>
	<first_name_fa>حمید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>قائدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ghaedi.hamid@yahoo.co.uk</email>
	<code>10031947532846003269</code>
	<orcid>10031947532846003269</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Islamic Azad University</affiliation>
	<affiliation_fa>دانشگاه آزاد اسلامی</affiliation_fa>
	 </author>


	<author>
	<first_name>Ghazanfar</first_name>
	<middle_name></middle_name>
	<last_name>Shahgholian</last_name>
	<suffix></suffix>
	<first_name_fa>غضنفر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شاهقلیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>shahgholiangh@gmail.com</email>
	<code>1289354952</code>
	<orcid>10031947532846003270</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Islamic Azad University</affiliation>
	<affiliation_fa>دانشگاه آزاد اسلامی</affiliation_fa>
	 </author>


	<author>
	<first_name>Mahnaz</first_name>
	<middle_name></middle_name>
	<last_name>Hashemi</last_name>
	<suffix></suffix>
	<first_name_fa>مهناز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>هاشمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>m.hashemi@ec.iut.ac.ir</email>
	<code>10031947532846003271</code>
	<orcid>10031947532846003271</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Islamic Azad University</affiliation>
	<affiliation_fa>دانشگاه آزاد اسلامی</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
