<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Electric Industry Journal of Quality and Productivity</title>
<title_fa>نشریه کیفیت و بهره وری صنعت برق ایران</title_fa>
<short_title>ieijqp</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ieijqp.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2344</journal_id_issn>
<journal_id_issn_online>2717-1639</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61186/ieijqp</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1398</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2019</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>8</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>الگوریتم مبتنی بر آنتروپی متقاطع برای آشکارسازی خطای امپدانس بالا در شبکه‌های توزیع</title_fa>
	<title>Cross Entropy-Based High-Impedance Fault Detection Algorithm for Distribution Networks</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;&lt;span dir=&quot;RTL&quot;&gt;جریان خطای کوچک&lt;/span&gt; &lt;span dir=&quot;RTL&quot;&gt;خطاهای امپدانس بالا یکی از چالش&#8204;های مهم حفاظت شبکه&#8204;های توزیع است. عدم توانایی آشکارسازی این نوع خطا توسط رله&#8204;های اضافه جریان مرسوم منجر به تداوم قوس الکتریکی ناشی از آنها می&#8204;شود که نتیجه آن&amp;nbsp; اتلاف انرژی، خطر آتش&lt;/span&gt;&amp;shy;&lt;span dir=&quot;RTL&quot;&gt;سوزی و شوک الکتریکی می&amp;shy;باشد که تهدیدی برای جان انسان&#8204;ها و تجهیزات شبکه است. در این مقاله یک الگوریتم آشکارسازی خطای امپدانس بالا بر مبنای کمّی &#8204;سازی ویژگی&#8204;های غیرخطی بودن و نامتقارن بودن شکل موج حاصل از خطا ارائه می&#8204;گردد. به این منظور ابتدا از جریان پست توزیع نمونه&#8204;برداری شده و سپس مؤلفه تحمیلی خطای سیگنال آنتروپی متقاطع حاصل از مقایسه شکل موج دو نیم سیکل متوالی جریان به عنوان شاخص آشکارسازی خطا محاسبه می&#8204;شود. از سوی دیگر برای غلبه بر چالش تشابه گذراهای ناشی از کلیدزنی تجهیزات و خطا، از زمان تداوم گذرا به عنوان قید شاخص پیشنهادی بهره برده می&#8204;شود. طرح پیشنهادی در حضور بار&amp;shy;های غیرخطی به خوبی کار کرده و نیازی به داده&amp;shy;های آموزشی، تبدیل و محاسبه &lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;مؤلفه&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&amp;shy;های هارمونیکی و متقارن ندارد. کارآیی الگوریتم پیشنهادی از طریق شبیه&amp;shy;سازی حوزه زمانی سیستم&amp;shy;&amp;shy; تست استاندارد 13 باسه &lt;/span&gt;IEEE&lt;span dir=&quot;RTL&quot;&gt; نشان داده می&#8204;شود.&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;
</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;The low fault current of high-impedance faults (HIFs) is one of the main challenges for the protection of distribution networks. The inability of conventional overcurrent relays in detecting these faults results in electric arc continuity that it causes the fire hazard and electric shock and poses a serious threat to human life and network equipment. This paper presents ​an HIF detection algorithm based on quantifying the nonlinear and asymmetry features of HIF waveforms. To this end, first, the substation current is sampled and then, the superimposed component of cross entropy signal calculated by comparing two subsequent half cycles of the current signal is determined as the HIF detection criteria. On the other hand, to overcome the challenge of the similar transient of device switching and HIF, the time duration of transient continuity is considered as the constraint of the proposed algorithm. The proposed scheme satisfactory works in the presence of nonlinear loads and does not need for training dataset, transformations, and calculation of harmonic and symmetrical components. The effectiveness of the proposed HIF detection algorithm is demonstrated using the time-domain simulation of IEEE 13 node test system.&lt;br&gt;
&amp;nbsp;&lt;/div&gt;
</abstract>
	<keyword_fa>خطای امپدانس بالا, شبکه توزیع, آنتروپی متقاطع, حفاظت</keyword_fa>
	<keyword>High-impedance fault, distribution network, cross entropy, protection</keyword>
	<start_page>62</start_page>
	<end_page>71</end_page>
	<web_url>http://ieijqp.ir/browse.php?a_code=A-10-1063-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Shiva</first_name>
	<middle_name></middle_name>
	<last_name>Nezamzadeh-Ejieh</last_name>
	<suffix></suffix>
	<first_name_fa>شیوا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نظام زاده اژیه</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>shiva.nezamzadeh@sel.iaun.ac.ir</email>
	<code>10031947532846003267</code>
	<orcid>10031947532846003267</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Najafabad Branch, Islamic Azad University</affiliation>
	<affiliation_fa>واحد نجف‌آباد، دانشگاه آزاد اسلامی</affiliation_fa>
	 </author>


	<author>
	<first_name>Iman</first_name>
	<middle_name></middle_name>
	<last_name>Sadeghkhani</last_name>
	<suffix></suffix>
	<first_name_fa>ایمان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صادق خانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>sadeghkhani@pel.iaun.ac.ir</email>
	<code>10031947532846003268</code>
	<orcid>10031947532846003268</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Najafabad Branch, Islamic Azad University</affiliation>
	<affiliation_fa>واحد نجف‌آباد، دانشگاه آزاد اسلامی</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>