<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Electric Industry Journal of Quality and Productivity</title>
<title_fa>نشریه کیفیت و بهره وری صنعت برق ایران</title_fa>
<short_title>ieijqp</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ieijqp.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2344</journal_id_issn>
<journal_id_issn_online>2717-1639</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61186/ieijqp</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1393</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2014</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>3</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی اثر بهره‏برداری بدون اپراتور از پست‏های فوق توزیع و انتقال بر قابلیت اطمینان پست</title_fa>
	<title>Analysis of the effect of unmanned operation of substations on the reliability indices of substation</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>هدف از این مقاله بررسی سطح قابلیت اطمینان پست‏های فوق توزیع و انتقال در اثر حذف اپراتور از پست‏ها و بهره‏برداری از راه دور آن توسط مرکز دیسپاچینگ است. برای رسیدن به این هدف در این مقاله راهکاری دو گامی ارائه شده است. در گام اول، ابتدا مطالعه‏ای مروری بر قابلیت اطمینان تجهیزات پست و نحوه مدل‏سازی آن‏ها شده است. سپس گزارش‏های آماری مختلفی از رفتار تصادفی تجهیزات پست بررسی شده است. هدف از این گام بررسی رفتار پارامترهای قابلیت اطمینان تجهیزات در اثر اعمال فرآیند اتوماسیون پست و بهره‏برداری از راه دور آن است. میزان تأثیر پذیری پارامترهای قابلیت اطمینان تجهیزات از فرآیند بهره‏برداری از راه دور پست بر اساس سطح اتوماسیون، نتایج مطالعات آماری و نیز تجربه مهندسین مجرب تعیین می‏شود. در گام دوم، با کمک روش مینیمال کات‏ست، شاخص‏های قابلیت اطمینان پست در دو حالت بهره‏برداری به روش مرسوم و نیز بهره‏برداری از راه دور پست (پست آنمن) بررسی شده است. با تشخیص مینیمال کات‏ست‏های موثر بر خروج هر پایانه می‏توان در فرآیند اتوماسیون پست به مانیتورینگ و تقویت المان‏های آن کات‏ست توجهی خاص نمود. نتایج مطالعات انجام شده در این مقاله نشان می‏دهد که سطح قابلیت اطمینان پست آنمن بیش از دو برابر سطح قابلیت اطمینان پست با بهره‏برداری مرسوم می‏باشد</abstract_fa>
	<abstract>The purpose of this paper is to investigate the reliability of the unmanned substations which operated remotely by dispatching center. In order to achieve this goal, this paper proposes a two step modeling method. At the first step, firstly we reviewed the reliability of substation equipment and its modeling. Then, by analyzing statistical reports, the stochastic behaviors of substation equipment were reviewed. The goal of this step is to investigate the behavior of equipment reliability parameters after applying unmanned operation if substations. This depends on the automation level, statistical studies and professional experience of engineers. In the second step, with the help of minimal cut-set method, the reliability of substation at two modes of operation of it (conventional &amp; unmanned) has been studied. This paper shows that the level of reliability of unmanned substations is more than twice the level of reliability of conventional substations
</abstract>
	<keyword_fa>: پست فوق توزیع و انتقال, بهره‏برداری بدون اپراتور پست, قابلیت اطمینان, مینیمال کات‏ست</keyword_fa>
	<keyword>substation, unmanned operation, reliability, minimal Cut-set </keyword>
	<start_page>38</start_page>
	<end_page>45</end_page>
	<web_url>http://ieijqp.ir/browse.php?a_code=A-10-184-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>iraj</first_name>
	<middle_name></middle_name>
	<last_name>zaker</last_name>
	<suffix></suffix>
	<first_name_fa>ایرج</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ذاکر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>iraj_zaker@yahoo.com</email>
	<code>1003194753284600711</code>
	<orcid>1003194753284600711</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>khorasan regional electric company</affiliation>
	<affiliation_fa>برق منطقه خراسان</affiliation_fa>
	 </author>


	<author>
	<first_name>mohammad ebrahim</first_name>
	<middle_name></middle_name>
	<last_name>Hajiabadi</last_name>
	<suffix></suffix>
	<first_name_fa>محمد ابراهیم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حاجی ابادی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>me.hajiabadi@hsu.ac.ir</email>
	<code>1003194753284600712</code>
	<orcid>1003194753284600712</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Hakim sabzevari unuversity</affiliation>
	<affiliation_fa>دانشگاه حکیم سبزواری</affiliation_fa>
	 </author>


	<author>
	<first_name>Habib</first_name>
	<middle_name></middle_name>
	<last_name>Rajabi Mashhadi</last_name>
	<suffix></suffix>
	<first_name_fa>حبیب</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رجبی مشهدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>h_mashhadi@um.ac.ir</email>
	<code>1003194753284600713</code>
	<orcid>1003194753284600713</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Ferdowsi university of mashhad</affiliation>
	<affiliation_fa>دانشگاه فردوسی مشهد</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
