<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Electric Industry Journal of Quality and Productivity</title>
<title_fa>نشریه کیفیت و بهره وری صنعت برق ایران</title_fa>
<short_title>ieijqp</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ieijqp.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2344</journal_id_issn>
<journal_id_issn_online>2717-1639</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61186/ieijqp</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1403</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2024</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>13</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>یک طرح حفاظتی مبتنی بر منحنی اصلاح شده ی رله اضافه جریان برای شبکه‌ های توزیع با سطح نفوذ بالای خودروهای الکتریکی</title_fa>
	<title>A Protection Scheme Based on Modified Curve of Overcurrent Relay for Distribution Systems with High Penetration Level of Electric Vehicles</title>
	<subject_fa>برق و کامپیوتر</subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span arial=&quot;&quot; dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;برای کاهش وابستگی حمل&#8204;ونقل به سوخت&#8204;های فسیلی، وسایل نقلیه الکتریکی رشد و کاربرد گسترده&#8204;ای پیدا کرده&#8204;اند، به&amp;not;گونه&amp;not;ای که تعداد ایستگاه&#8204;های شارژ مربوط به آنها افزایش داشته است. افزایش سطح نفوذ ایستگاه&#8204;های شارژ خودروهای الکتریکی در شبکه توزیع، مشخصه جریان خطا را پیچیده&#8204;تر کرده است که منجر به قطع انرژی نامطلوب بارها، آسیب به تجهیزات شبکه و کاهش قابلیت اطمینان می&#8204;گردد. این مقاله روشی را برای حفظ هماهنگی حفاظتی با در نظر گرفتن ایستگاه&#8204;های شارژ خودروهای الکتریکی با سطوح نفوذ مختلف و مکان&#8204;های گوناگون در امتداد فیدر توزیع معرفی می&#8204;کند. با شناسایی بدترین حالت تأثیر خودروهای الکتریکی متصل شده به شبکه توزیع در ناهماهنگی حفاظتی، منحنی مشخصه حفاظت مرسوم شبکه توزیع اصلاح می&#8204;شود. طرح پیشنهادی ساختار سیستم حفاظتی فعلی شبکه توزیع را تغییر نمی&#8204;دهد و می&#8204;تواند با رله&#8204;های قدیمی و غیرقابل برنامه&#8204;ریزی نیز اجرا شود. علاوه بر این، نیازی به ارتباط مخابراتی ندارد. نتایج شبیه سازی نشان می دهد فاصله زمانی هماهنگی در روش پشنهادی و در زمان اتصال خودروهای الکتریکی مابین رله های اصلی و پشتیبان، در مقدار 300 میلی ثانیه حفظ می شود. همچنین با اعمال الگوریتم پیشنهادی و در شرایط اتصال خودروهای الکتریکی به شبکه توزیع در بالادست رله پشتیبان، حد مجاز حرارتی هادی&amp;not;های شبکه (1000 میلی ثانیه) تضمین می گردد&lt;/span&gt;.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;To reduce transportation&amp;#39;s dependence on fossil fuels, electric vehicles (EVs) have gained widespread acceptance, which has led to an increase in the number of charging stations. With the increasing penetration level of EV charging stations in the distribution system, the fault current characteristic has become more complicated, which leads to frequent undesired power outages, damage to network equipment, and reduced reliability. This paper presents a scheme to preserve protection coordination by considering EV charging stations with different penetration levels and various locations along the distribution feeder. By identifying the worst-case impact of integrated EVs into the distribution system on the protection miscoordination, the characteristic curve of conventional protection is modified. The proposed scheme does not change the structure of the existing protection system of the distribution network and can be implemented with old and non-programmable relays. In addition, it does not require communication links. The simulation results show that the coordination time interval in the proposed method and during the connection of electric vehicles between the main and backup relays is maintained at 300 milliseconds. Also, with the application of the proposed algorithm and in the condition of connecting electric vehicles to the distribution network upstream of the backup relay, the thermal limit of the network conductors (1000 milliseconds) is ensured.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract>
	<keyword_fa>شبکه توزیع, هماهنگی حفاظتی, خودروی الکتریکی, حفاظت اضافه جریان</keyword_fa>
	<keyword>Distribution system, electric vehicle, overcurrent protection, protection coordination</keyword>
	<start_page>60</start_page>
	<end_page>77</end_page>
	<web_url>http://ieijqp.ir/browse.php?a_code=A-10-799-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Majid</first_name>
	<middle_name></middle_name>
	<last_name>Tavoosi</last_name>
	<suffix></suffix>
	<first_name_fa>مجید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>طاوسی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mtavoosi84@gmail.com</email>
	<code>10031947532846007690</code>
	<orcid>10031947532846007690</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Isfahan(Khorasgan) Branch, Islamic Azad University,Isfahan, Iran</affiliation>
	<affiliation_fa>1-	دانشکده فنی مهندسی، واحد اصفهان (خوراسگان)، دانشگاه آزاد اسلامی، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Bahador</first_name>
	<middle_name></middle_name>
	<last_name>Fani</last_name>
	<suffix></suffix>
	<first_name_fa>بهادر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>b.fani@khuisf.ac.ir</email>
	<code>10031947532846007691</code>
	<orcid>10031947532846007691</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Electrical Engineering, Isfahan(Khorasgan) Branch, Islamic Azad University,Isfahan, Iran</affiliation>
	<affiliation_fa>1-	دانشکده فنی مهندسی، واحد اصفهان (خوراسگان)، دانشگاه آزاد اسلامی، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Majid</first_name>
	<middle_name></middle_name>
	<last_name>Delshad</last_name>
	<suffix></suffix>
	<first_name_fa>مجید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>دلشاد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>delshad@khuisf.ac.ir</email>
	<code>10031947532846007692</code>
	<orcid>10031947532846007692</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Isfahan(Khorasgan) Branch, Islamic Azad University,Isfahan, Iran</affiliation>
	<affiliation_fa>1-	دانشکده فنی مهندسی، واحد اصفهان (خوراسگان)، دانشگاه آزاد اسلامی، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Iman</first_name>
	<middle_name></middle_name>
	<last_name>Sadeghkhani</last_name>
	<suffix></suffix>
	<first_name_fa>ایمان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صادق‌خانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>sadeghkhani@pel.iaun.ac.ir</email>
	<code>10031947532846007693</code>
	<orcid>10031947532846007693</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Najafabad Branch, Islamic Azad University, Najafabad 85141-43131, Iran</affiliation>
	<affiliation_fa>3-	دانشکده مهندسی برق، واحد نجف ‌آباد، دانشگاه آزاد اسلامی، نجف ‌آباد، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
