<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Electric Industry Journal of Quality and Productivity</title>
<title_fa>نشریه کیفیت و بهره وری صنعت برق ایران</title_fa>
<short_title>ieijqp</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ieijqp.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2344</journal_id_issn>
<journal_id_issn_online>2717-1639</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61186/ieijqp</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>5</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>جایابی، تعیین اندازه و برنامه ریزی بهینه پست های فوق توزیع با استفاده از ذخیره سازهای باتری جریانی وانادیوم به منظور افزایش بهره وری شبکه توزیع برق</title_fa>
	<title>Placement, sizing and optimal scheduling subtransmission using vanadium flow battery storage in order to increase the efficiency of the distribution network</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p&gt;&lt;span dir=&quot;RTL&quot;&gt;ذخیره&amp;shy; سازی انرژی الکتریکی یکی از مسائل مهم صنعت برق است که می&amp;shy;تواند خدمات جانبی بسیاری همچون تسطیح منحنی بار، پیک&amp;shy; سایی، ادغام با واحدهای تجدیدپذیر، رزرو چرخان و ... را عاید شبکه سازد. در این مقاله یک روش جدید و کاربردی به منظور جایابی، تعیین اندازه و برنامه &amp;shy;ریزی بهینه ذخیره&amp;shy; ساز باتری جریانی وانادیوم در پست&amp;shy; های فوق توزیع ارائه می&amp;shy; گردد. در این روش ابتکاری، با استفاده از پیش&amp;shy; بینی بار، مقدار مصرف روز پیک محاسبه شده و براساس آن چندین شاخص برای اولویت&amp;shy; بندی مکان نصب ذخیره &amp;shy;ساز تعریف می&amp;shy; شود. سپس با توجه به اطلاعات توان مصرفی در پست انتخاب شده، ظرفیت بهینه ذخیره&amp;shy; ساز برای تسطیح منحنی بار تعیین شده و در نهایت یک برنامه&amp;shy; ریزی بهینه برای شارژ و دشارژ ذخیره &amp;shy;ساز ارائه می&amp;shy; گردد. در این مقاله، برای شبیه&amp;shy; سازی از داده&amp;shy; های واقعی مصرف شبکه فوق توزیع شهرستان سمنان استفاده شده است. &amp;nbsp;&lt;/span&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;em&gt;There are many advantages to utilize storages in electric power system. Peak shaving, load leveling, load frequency control, integration of renewable, energy trading and spinning reserve are the most important of them. Batteries, especially redox flow batteries, are one of the appropriate storages for utilization in distribution network. This paper presents a novel, heuristic and practical method for optimal scheduling in distribution network with flow battery storage. &lt;span id=&quot;result_box&quot; lang=&quot;en&quot;&gt;&lt;span class=&quot;hps&quot;&gt;This innovative method&lt;/span&gt; &lt;span class=&quot;hps&quot;&gt;to&lt;/span&gt; &lt;span class=&quot;hps&quot;&gt;enhance the efficiency&lt;/span&gt; &lt;span class=&quot;hps&quot;&gt;posts&lt;/span&gt; &lt;span class=&quot;hps&quot;&gt;that&lt;/span&gt; &lt;span class=&quot;hps&quot;&gt;are&lt;/span&gt; &lt;span class=&quot;hps&quot;&gt;needed&lt;/span&gt; &lt;span class=&quot;hps&quot;&gt;to install&lt;/span&gt; &lt;span class=&quot;hps&quot;&gt;storage&lt;/span&gt; &lt;span class=&quot;hps&quot;&gt;is&lt;/span&gt; &lt;span class=&quot;hps&quot;&gt;very convenient&lt;/span&gt;&lt;span&gt;.&lt;/span&gt;&lt;/span&gt; Peak shaving and load leveling is considered as the main objective in this paper. Several indices are presented in this paper for determine the place of storages and also scheduling for optimal use of energy in them. Simulations of this paper are based on real information of distribution network substation that located in Semnan, Iran.&lt;/em&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>باتری جریانی, پیک سایی, تسطیح منحنی بار, ذخیره سازی انرژی</keyword_fa>
	<keyword>energy storage, flow battery, peak shaving, load leveling </keyword>
	<start_page>73</start_page>
	<end_page>82</end_page>
	<web_url>http://ieijqp.ir/browse.php?a_code=A-10-591-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>majid</first_name>
	<middle_name></middle_name>
	<last_name>hosseina</last_name>
	<suffix></suffix>
	<first_name_fa>مجید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسینا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>majidhosseina@gmail.com</email>
	<code>10031947532846002162</code>
	<orcid>10031947532846002162</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>khaje nasir universitu</affiliation>
	<affiliation_fa>دانشگاه صنعتی خواجه نصیر</affiliation_fa>
	 </author>


	<author>
	<first_name>seyed mohammad taghi</first_name>
	<middle_name></middle_name>
	<last_name>bathaee</last_name>
	<suffix></suffix>
	<first_name_fa>سید محمدتقی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بطحائی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>bathaee@kntu.ac.ir</email>
	<code>10031947532846002163</code>
	<orcid>10031947532846002163</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>khaje nasir university</affiliation>
	<affiliation_fa>دانشگاه صنعتی خواجه نصیر</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>