<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Electric Industry Journal of Quality and Productivity</title>
<title_fa>نشریه کیفیت و بهره وری صنعت برق ایران</title_fa>
<short_title>ieijqp</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ieijqp.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2344</journal_id_issn>
<journal_id_issn_online>2717-1639</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61186/ieijqp</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>5</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>برنامه ریزی بهینه ی باتری ها در شبکه توزیع فعال با در نظر گرفتن تکنولوژی های مختلف در شرایط فنی و اقتصادی غیرقطعی </title_fa>
	<title>Optimal Planning of Batteries in Distribution Network Considering Various Technologies in Different Technical and Economic Conditions</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p&gt;&lt;span dir=&quot;RTL&quot;&gt;با توجه به اهمیت ذخیره انرژی در شبکه&amp;shy; های توزیع فعال و همچنین وجود تکنولوژی&amp;shy;های مختلف برای باتری&amp;shy; ها، در این مقاله، برنامه &amp;shy;ریزی بهینه انواع باتری&amp;shy;ها، با هدف مقایسه&amp;shy; ی انواع تکنولوژی&amp;shy; ها ارائه شده است. در یک برنامه&amp;shy; ریزی بلندمدت، نوع، مکان نصب، ظرفیت و توان نامی باتری&amp;shy; ها باید به طور بهینه تعیین شود. تابع هدف شامل هزینه&amp;shy; های سرمایه&amp;shy; گذاری، تعمیرات و نگهداری، بهره &amp;shy;برداری شبکه و شاخص&amp;shy; های قابلیت اطمینان است. قیود سطح ولتاژ، ظرفیت تجهیزات و تعادل توان در شبکه باید در کل دوره&amp;shy; ی برنامه&amp;shy; ریزی رعایت شوند. از طرف دیگر، هر تکنولوژی دارای پارامترهای فنی و اقتصادی غیرقطعی مخصوص به خود است که در زمان&amp;shy; ها و موقعیت&amp;shy; های مختلف تغییر می &amp;shy;کند. بنابراین در یک مطالعه&amp;shy; ی جامع، عدم قطعیت پارامترهای باتری، در کنار سایر مشخصات غیرقطعی سیستم مد نظر قرار گرفته است. مسأله&amp;shy; ی عدم قطعیت، با استفاده از تحلیل&amp;shy; های فازی مدلسازی می&amp;shy; شود و برای بهینه&amp;shy; سازی از الگوریتم تبرید تدریجی استفاده شده است. نتایج به دست آمده در این مطالعه نشان می&amp;shy;دهد که تکنولوژی Zn-Br در شرایط میانگین، از سایر انواع مناسب&amp;shy; تر است. با اینحال در شرایط غیر قطعی، تکنولوژی NaS می&amp;shy; تواند با Zn-Br رقابت کرده و گزینه &amp;shy;ای بهینه باشد. در نهایت با اجرای تحلیل حساسیت، نتایج به دست آمده به شبکه&amp;shy; های مختلف تعمیم داده می&amp;shy; شوند.&lt;/span&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;Regarding the importance of energy storage in distribution networks and different battery technologies, in this paper the optimal battery planning is presented to compare different technologies without renewable energies in the grid. In long-term planning, the decision variables are the battery type, location, capacity and power rating which should be determined optimally. The objective function includes investment cost and O &amp; M cost of battery as well as the grid operation and reliability cost. The technical constraints should be satisfied in project period as well. On the other hand, every technology has its own technical and economic parameters which change in different conditions. As a result, different parameters of the batteries as well as the behavior of the system are taken into account in a comprehensive study. The simulated annealing algorithm is used for optimization. This study show the Zn-Br and Na-S are the most suitable technologies. The results are generalized to different distribution networks using several sensitivity analyses. Finally, it is specified that employing the batteries is economical in those distribution grids which are connected to the global network and have not renewable distributed energy resources.&amp;nbsp; &amp;nbsp;&lt;/p&gt;
</abstract>
	<keyword_fa>شبکه توزیع فعال, ذخیره انرژی, بهینه سازی, قابلیت اطمینان, عدم قطعیت</keyword_fa>
	<keyword>Active distribution network, energy storage, optimization, reliability, uncertainty</keyword>
	<start_page>14</start_page>
	<end_page>24</end_page>
	<web_url>http://ieijqp.ir/browse.php?a_code=A-10-23-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Majid</first_name>
	<middle_name></middle_name>
	<last_name>Daghi</last_name>
	<suffix></suffix>
	<first_name_fa>مجید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>داغی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>daghi_majid@yahoo.com</email>
	<code>10031947532846002148</code>
	<orcid>10031947532846002148</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>K. N. Toosi University of Technology</affiliation>
	<affiliation_fa>دانشگاه صنعتی خواجه نصیرالدین طوسی</affiliation_fa>
	 </author>


	<author>
	<first_name>Mahdi</first_name>
	<middle_name></middle_name>
	<last_name>Sedghi</last_name>
	<suffix></suffix>
	<first_name_fa>مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صدقی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>meh.sedghi@gmail.com</email>
	<code>10031947532846002149</code>
	<orcid>10031947532846002149</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>K. N. Toosi University of Technology</affiliation>
	<affiliation_fa>دانشگاه صنعتی خواجه نصیرالدین طوسی</affiliation_fa>
	 </author>


	<author>
	<first_name>Masoud</first_name>
	<middle_name></middle_name>
	<last_name>Aliakbar-Golkar</last_name>
	<suffix></suffix>
	<first_name_fa>مسعود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علی اکبر گلکار</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>golkar@eetd.kntu.ac.ir</email>
	<code>10031947532846002150</code>
	<orcid>10031947532846002150</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>K. N. Toosi University of Technology</affiliation>
	<affiliation_fa>دانشگاه صنعتی خواجه نصیرالدین طوسی</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
