<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Electric Industry Journal of Quality and Productivity</title>
<title_fa>نشریه کیفیت و بهره وری صنعت برق ایران</title_fa>
<short_title>ieijqp</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ieijqp.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2344</journal_id_issn>
<journal_id_issn_online>2717-1639</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61186/ieijqp</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1404</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2025</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>14</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>یک طرح تخمین فاصله و بخش خطا در میکروگرید با استفاده از اندازه ولتاژ در ابتدای شبکه و حداقل مربعات</title_fa>
	<title>A scheme for fault distance and section estimation in microgrid using voltage magnitude measurement at the beginning of the grid and least squares</title>
	<subject_fa>برق و کامپیوتر</subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;میکروگریدها در معرض انواع خطا قرار دارند و شناسایی سریع محل خطا برای کاهش خاموشی، جلوگیری از آسیب تجهیزات و بهبود شاخص&#8204;های قابلیت اطمینان ضروری است. این مقاله یک طرح دو &#8204;مرحله&#8204;ای برای بخش&#8204;یابی و فاصله&#8204;یابی خطا ارائه می&#8204;کند که تنها به اختلاف اندازه ولتاژ در نقطه اتصال مشترک&lt;/span&gt; &lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;متکی است و از تقریب حداقل مربعات برای برآورد فاصله استفاده می&#8204;کند. در گام نخست، با محاسبه اختلاف اندازه ولتاژ قبل و بعد از وقوع خطا&lt;/span&gt;&amp;nbsp; &lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;و مقایسه آن با &lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot;&gt;اختلاف اندازه ولتاژهای&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt; شبیه&#8204;سازی&#8204;شده در بخش&#8204;های مختلف، شاخصی تعریف می&#8204;شود که کمینه آن، بخش خطادار را تعیین می&#8204;کند. سپس در همان بخش، با شبیه&#8204;سازی خطاهایی مشابه خطای واقعی در گام&#8204;های 100 متری، یک بانک داده آنلاین تولید و منحنی &lt;/span&gt;&amp;nbsp;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot;&gt;اختلاف اندازه ولتاژ خطا - &lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;فاصله، با چندجمله&#8204;ای درجه&#8204;دو برازش می&#8204;شود تا فاصله خطا به&#8204;صورت تحلیلی به دست آید&lt;/span&gt;.&lt;span dir=&quot;RTL&quot;&gt; در &lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;روش پیشنهادی &lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot;&gt;از &lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;مدل&lt;/span&gt; &amp;pi; &lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;خط (با لحاظ خازنِ خطوط) برای افزایش دقت استفاده شده و از داده&#8204;های جریان، جهت جریان و حالت اشباع ترانسفورماتور مستقل است؛ همچنین به سامانه&#8204;های مخابراتی پیشرفته و همگام&#8204;سازی داده&#8204;ها نیاز ندارد. ارزیابی در شبکه استاندارد&lt;/span&gt; IEEE 15 &lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;گره اصلاح&#8204;شده و با حضور منابع تولید پراکنده نشان می&#8204;دهد روش پیشنهادی ضمن تشخیص صحیح بخش خطادار، در گستره&#8204;ای از مقاومت خطا و زاویه شروع خطا و ضرایب نفوذ&lt;/span&gt; &lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot;&gt;&amp;nbsp;منابع تجدید پذیر&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;، دقت فاصله&#8204;یابی قابل قبول (99%) دارد. این ویژگی&#8204;ها، در کنار اتکا به یک اندازه&#8204;گیر ولتاژ در ابتدای شبکه، سادگی در پیاده&#8204;سازی و هزینه پایین را برای بهره&#8204;بردار فراهم می&#8204;کند&lt;/span&gt;.&lt;br&gt;
&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;Microgrids are exposed to various types of faults, and the fast identification of fault location is essential for minimizing outages, preventing equipment damage, and improving reliability indices. This paper presents a two-stage scheme for fault section identification and fault distance estimation, relying solely on the voltage magnitude difference at the point of common coupling (PCC) and employing a least-squares approximation for distance estimation. In the first stage, the voltage magnitude difference pre and post fault is calculated and compared with simulated voltage differences across different sections; the section corresponding to the minimum index is identified as the faulty one. In the second stage, within the identified section, faults similar to the actual fault are simulated at 100-meter intervals to build an online databank. The relationship between the fault-induced voltage difference and the fault distance is then fitted with a quadratic polynomial, enabling analytical determination of the fault location. To enhance accuracy, the proposed method employs the &amp;pi;-line model (including line capacitance) and is independent of current data, current direction, and transformer saturation effects. Moreover, it does not require advanced communication systems or data synchronization. Evaluation on a modified IEEE 15-bus test system with distributed generation demonstrates that the proposed approach correctly identifies the faulty section and achieves a high fault location accuracy (99%) across a wide range of fault resistances, fault inception angles, and penetration levels of renewable resources. These features, combined with reliance on a single voltage measurement at the feeder head, make the method simple, cost-effective, and practical for real-world applications.&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>مکان‌یابی خطا, میکروگرید, اندازه ولتاژ, حداقل مربعات, نقطه اتصال مشترک</keyword_fa>
	<keyword>Fault Location, Microgrid, Voltage Magnitude, Least Squares, Point of Common Coupling</keyword>
	<start_page>34</start_page>
	<end_page>43</end_page>
	<web_url>http://ieijqp.ir/browse.php?a_code=A-10-1597-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Golnaz</first_name>
	<middle_name></middle_name>
	<last_name>Abasi</last_name>
	<suffix></suffix>
	<first_name_fa>گلناز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عباسی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>abasigolnaz90@gmail.com</email>
	<code>2820055052</code>
	<orcid>10031947532846007548</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده فنی مهندسی- واحد تهران مرکز - دانشگاه آزاد اسلامی –تهران- ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mahmood</first_name>
	<middle_name></middle_name>
	<last_name>Hosseini Aliabadi</last_name>
	<suffix></suffix>
	<first_name_fa>محمود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسینی علی آبادی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mah.hosseini-aliabadi@iauctb.ac.ir</email>
	<code>5789777597</code>
	<orcid>10031947532846007547</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده فنی مهندسی- واحد تهران مرکز - دانشگاه آزاد اسلامی –تهران- ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>mohammad</first_name>
	<middle_name></middle_name>
	<last_name>daisy</last_name>
	<suffix></suffix>
	<first_name_fa>محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>دیسی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>moh.daisy.eng@iauctb.ac.ir</email>
	<code>3501028768</code>
	<orcid>10031947532846007549</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده فنی مهندسی- واحد تهران مرکز - دانشگاه آزاد اسلامی –تهران- ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
