fault detection in microgrids using positive, negative and zero sequences of voltage and current waveforms considering uncertainties of network topology
Reza Eslami1 , Seyed hossein hesamedin Sadeghi * 1, Hossein Askarian1
1- Amirkabir university of technology
Abstract:   (4999 Views)

In this paper a new method for fault detection in microgrids is proposed considering uncertainties of their networks topologies. The new method is realized by wavelet and S transforms. The properties of three phase components and positive, negative and zero sequences of current and voltage waveforms which are used in fault detection, fault location and to determining the occurred fault type are mined by wavelet and S transforms. For this reason that the process of the fault detection in this method is independent from the network topology, so this method is capable to detect occurred faults in all dynamic states of the studied microgrid. To check the ability of the proposed method in fault detection, this method is implemented on a sample microgrid. The simulation results show that the proposed method is capable to distinguish between the occurred faults and the transient distortions in the network. Also the comparison of S transform and wavelet transform shows that although wavelet transform usage exceeds the speed of maintaining a decision, but the accuracy of S transform in differentiate between the occurred states in microgird is the premier property of this transform.

Keywords: fault detection, positive and negative and zero sequences, wavelet transform, S transform, signal energy
Full-Text [PDF 1794 kb]   (5138 Downloads)    
Type of Study: Research | Subject: Special
Received: 2017/01/25 | Accepted: 2017/08/8 | Published: 2018/03/11
References
1. [1] G. G. Karady and L. Xing, "Fault management and protection of FREEDM systems", IEEE Power and Energy Society General Meeting, pp. 1-4, 2010.
2. [2] P. Tatcho, et al., "A novel line section protection for the FREEDM system based on the solid state transformer", IEEEPower and Energy Society General Meeting, pp. 1-8, 2011.
3. [3] J. J. Justo, et al., "AC-microgrids versus DC-microgrids with distributed energy resources: A review", Renewable and sustainable energy reviews, vol. 24, pp. 387-405, 2013.
4. [4] C. R. Pinnegar and L. Mansinha, "Time-local Fourier analysis with a scalable, phase-modulated analyzing function: the S-transform with a complex window", Signal Processing, vol. 84, pp. 1167-1176,2004.
5. [5] V. Terzija, et al., "Wide-Area Monitoring, Protection, and Control of Future Electric Power Networks",IEEE Proceedings, vol. 99, pp. 80-93, 2011.
6. [6] T. Liang, et al., "From laboratory Microgrid to real markets - Challenges and opportunities",IEEE 8th International Conference on Power Electronics and ECCE Asia (ICPE & ECCE), pp. 264-271, 2011.
7. [7] T. S. Ustun, et al., "Modeling of a Centralized Microgrid Protection System and Distributed Energy Resources According to IEC 61850-7-420",IEEE Transactions on Power Systems, vol. 27, pp. 1560-1567, 2012.
8. [8] W. Jiang, et al., "The Overview of Research on Microgrid Protection Development", International Conference in Intelligent System Design and Engineering Application, pp. 692-697, 2010.
9. [9] A. A. Memon and K. Kauhaniemi, "A critical review of AC Microgrid protection issues and available solutions", Electric Power Systems Research, vol. 129, pp. 23-31, 2015.
10. [10] Z. Kai-Hui and X. Ming-Chao, "Impacts of microgrid on protection of distribution networks and protection strategy of microgrid",International Conference on in Advanced Power System Automation and Protection (APAP), pp. 356-359, 2011.
11. [11] M. A. Redfern and H. Al-Nasseri, "Protection of micro-grids dominated by distributed generation using solid state converters", 9th International Conference on Developments in Power System Protection, pp. 670-674, 2008.
12. [12] S. A. Hosseini, et al., "An overview of microgrid protection methods and the factors involved", Renewable and Sustainable Energy Reviews, vol. 64, pp. 174-186, 2016.
13. [13] P. Basak, et al., "A literature review on integration of distributed energy resources in the perspective of control, protection and stability of microgrid", Renewable and Sustainable Energy Reviews, vol. 16, pp. 5545-5556, 2012.
14. [14] H. Al-Nasseri, et al., "A voltage based protection for micro-grids containing power electronic converters", IEEE Power Engineering Society General Meeting, 2006.
15. [15] S. A. Hosseini, et al., "presenting a new method for identifing fault location in microgrids, using harmonic impedance", Iranian Journal of Science and Technology Transactions of Electrical Engineering, vol. 39, pp. 167-182, 2015.
16. [16] A. M. El-Zonkoly, "Fault diagnosis in distribution networks with distributed generation", Electric Power Systems Research, vol. 81, pp. 1482-1490, 2011.
17. [17] S. A. Saleh, et al., "Implementing and testing d-q WPT-based digital protection for micro-grid systems", IEEE Industry Applications Society Annual Meeting (IAS), pp. 1-8, 2011.
18. [18] S. R. Samantaray, et al., "Differential energy based microgrid protection against fault conditions", IEEE PES in Innovative Smart Grid Technologies (ISGT), pp. 1-7, 2012.
19. [19] H. Al-Nasseri and M. A. Redfern, "Harmonics content based protection scheme for Micro-grids dominated by solid state converters", 12th International Middle-East in Power System Conference, pp. 50-56,2008.
20. [20] M. Petit, et al., "Directional relays without voltage sensors for distribution networks with distributed generation: Use of symmetrical components", Electric Power Systems Research, vol. 80, pp. 1222-1228, 2010.
21. [21] M. A. Zamani, et al., "A Protection Strategy and Microprocessor-Based Relay for Low-Voltage Microgrids",IEEE Transactions on Power Delivery, vol. 26, pp. 1873-1883, 2011.
22. [22] I. Daubechies, "The wavelet transform, time-frequency localization and signal analysis", IEEE Transactions on Information Theory, vol. 36, pp. 961-1005, 1990.
23. [23] P. K. Ray, et al., "Disturbance detection in grid-connected distributed generation system using wavelet and S-transform", Electric Power Systems Research, vol. 81, pp. 805-819, 2011.
24. [24] P. Tatcho, L. Hui, J. Yu, and Q. Li, "A Novel Hierarchical Section Protection Based on the Solid State Transformer for the Future Renewable Electric Energy Delivery and Management (FREEDM) System", IEEE Transactions on Smart Grid, vol. 4, pp. 1096-1104, 2013.
25. S. K. Rudion, N. Hatziargyiou, S. Papathanassiou, K. Strunz, O. Ruhle, A. Orths, B. Rozel. Development of Benchmarks for Low and Medium Voltage Distribution Networks with High Penetration of Dispersed Generation [Online]


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

eslami R, sadeghi S H H, askarian H. fault detection in microgrids using positive, negative and zero sequences of voltage and current waveforms considering uncertainties of network topology. ieijqp 2018; 6 (2) :107-121
URL: http://ieijqp.ir/article-1-414-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 6, Issue 2 (3-2018) Back to browse issues page
نشریه علمی- پژوهشی کیفیت و بهره وری صنعت برق ایران Iranian Electric Industry Journal of Quality and Productivity
Persian site map - English site map - Created in 0.05 seconds with 39 queries by YEKTAWEB 4645