<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Electric Industry Journal of Quality and Productivity</title>
<title_fa>نشریه کیفیت و بهره وری صنعت برق ایران</title_fa>
<short_title>ieijqp</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ieijqp.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-2344</journal_id_issn>
<journal_id_issn_online>2717-1639</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61186/ieijqp</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1404</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2025</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<volume>14</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>اولویت‌بندی پارامترهای ریزشبکه با درنظرگرفتن عدم‌قطعیت‌ها به منظور استفاده در مطالعات حفاظتی</title_fa>
	<title>Prioritization of Microgrid Parameters Considering Uncertainties for Use in Protection Studies</title>
	<subject_fa>برق و کامپیوتر</subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp;تغییرات گسترده اندازه جریان خطا در شرایط مختلف بهره&#8204;برداری، باعث ایجاد چالش&#8204;های جدی در حفاظت معمول اضافه جریان در ریزشبکه شده&#8204;است. با درنظر گرفتن عدم&#8204;قطعیت&#8204;های مختلف، حفاظت اضافه جریان معمول بر اساس مشخصه&#8204;های استاندارد، دچار ناهماهنگی می&#8204;شود. یک راه حل برای رفع این مشکل، انتخاب پارامتری غیر از جریان جهت تشخیص خطا و استفاده در منحنی مشخصه رله&#8204;های ریزشبکه می&#8204;باشد. این انتخاب نیاز به مطالعه رفتار ذاتی پارامترهای قابل اندازه&#8204;گیری در محل رله&#8204;های اصلی و پشتیبان&#8204; به&#8204;ازای وقوع عدم&#8204;قطعیت&#8204;های مختلف و با درنظر گرفتن شرایط مختلف خطا در ریزشبکه دارد. در این مقاله برای انتخاب بهترین پارامتر قابل اندازه&#8204;گیری به&#8204;منظور استفاده در مشخصه رله&#8204;های ریزشبکه، سه شاخص پیشنهاد شده&#8204;است. این شاخص&#8204;ها میزان تاثیر هر یک از عدم&#8204;قطعیت&#8204;ها بر پارامترهای قابل اندازه&#8204;گیری را مشخص می&#8204;کنند. عدم&#8204;قطعیت&#8204;های مورد بررسی در این مقاله خروج منابع تولید پراکنده، جزیره&#8204;ای شدن، تغییر امپدانس شبکه بالادست، تغییر در نوع خطا و اندازه مقاومت خطا درنظر گرفته&#8204;شده&#8204;است. &lt;a name=&quot;_Hlk180569488&quot;&gt;شاخص&#8204;های معرفی&#8204;شده شامل شاخص میانگین مربعات خطا (&lt;/a&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;MSE&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;)، شاخص بررسی امکان وقوع نقض قید هماهنگی و شاخص مینیممِ تفاضل فاصله بین منحنی&#8204;های رله اصلی و پشتیبان در ساختار پس از وقوع عدم قطعیت نسبت به فاصله بین این منحنی&#8204;ها در ساختار پایه، می&#8204;باشند. پس از محاسبه شاخص&#8204;ها، به&#8204;منظور مقایسه پارامترها جهت انتخاب پارامترهای بهتر، اولویت&#8204;بندی آن&#8204;ها با استفاده از روش&#8204;های مقایسه&#8204;ای پیشنهادی بردا و بردای وزنی انجام شده&#8204;است. &lt;a name=&quot;_Hlk182336010&quot;&gt;ویژگی&#8204; اصلی این روش&#8204;های مقایسه&#8204;ای این است که در آن&#8204;ها عمل مقایسه به&#8204;ازای هر عدم قطعیت به&#8204;صورت مجزا و به&#8204;شکل نظیر به نظیر بین پارامترهای مورد مطالعه انجام می&#8204;شود. &lt;/a&gt;&lt;a name=&quot;_Hlk182339533&quot;&gt;با استفاده از مطالعات آنالیز حساسیت و انجام شبیه&#8204;سازی بر روی بخش توزیع شبکه 14 شینه &lt;/a&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;IEEE&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;که به عنوان یک ریزشبکه درنظرگرفته شده، اثربخشی شاخص&#8204;ها و روش&#8204;های مقایسه&#8204;ای پیشنهادی اثبات گردیده و پارامترها جهت تشخیص خطا و استفاده در منحنی مشخصه رله&#8204;های ریزشبکه مذکور اولویت&#8204;بندی شده&#8204;است.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:12pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot;B Nazanin&quot;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp;The wide variations in fault current magnitude under different operating conditions pose serious challenges to conventional overcurrent protection in microgrid. Considering various uncertainties, conventional overcurrent protection based on standard characteristics, loses its coordination. One solution to this problem is to select a parameter other than current for fault detection and use it in the characteristic curve of microgrid relays. This selection requires studying the intrinsic behavior of measurable parameters at the location of primary and backup relays under various uncertainties and with considering different fault conditions in the microgrid. In this paper, three indices are proposed for selecting the best measurable parameter to be used in the characteristic curve of microgrid relays. These indices determine the impact of each uncertainty on the measurable parameters. The uncertainties considered in this paper include the outage of distributed generation sources, islanding, change in the impedance of the upstream network, change in fault type and fault resistance magnitude. The proposed indices include the Mean Square Error (MSE) index, the index for examining the possibility of the occurrence of coordination constraint violation and the index of minimum difference between the distance of the primary and backup relay curves in the post-uncertainty structure compared to the distance between these curves in the base structure. After calculating the indices, to compare the parameters for selecting the better ones, they are prioritized using the proposed Borda and Weighted Borda comparison methods. The main feature of these comparison methods is that the comparison is performed for each uncertainty separately and in a pairwise manner between the studied parameters. Using sensitivity analysis studies and simulations on the IEEE 14-bus distribution network considered as a microgrid, the effectiveness of the proposed indices and comparison methods has been proven, and the parameters have been prioritized for fault detection and use in the characteristic curve of the mentioned microgrid relays.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>ریزشبکه, عدم قطعیت, اولویت‌بندی پارامترهای ریزشبکه, روش بردا, روش  بردا وزنی, استانداردسازی, تولید پراکنده, تشخیص خطا</keyword_fa>
	<keyword>Microgrid, Uncertainty, Microgrid Parameter Prioritization, Borda Method, Weighted Borda Method, Standardization, Distributed Generation (DG), Fault detection.</keyword>
	<start_page>66</start_page>
	<end_page>80</end_page>
	<web_url>http://ieijqp.ir/browse.php?a_code=A-10-501-5&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Abbas</first_name>
	<middle_name></middle_name>
	<last_name>Saberi Noughabi</last_name>
	<suffix></suffix>
	<first_name_fa>عباس</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صابری نوقابی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>a.saberi@birjand.ac.ir</email>
	<code>0919589391</code>
	<orcid>10031947532846007357</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Electrical and Computer Engineering, University of Birjand, Birjand, Iran </affiliation>
	<affiliation_fa>دانشکده مهندسی برق و کامپیوتر -دانشگاه بیرجند-بیرجند- ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Saeed</first_name>
	<middle_name></middle_name>
	<last_name>Yeganehfar</last_name>
	<suffix></suffix>
	<first_name_fa>سعید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یگانه فر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>s_yeganeyfar@birjand.ac.ir</email>
	<code>0946402825</code>
	<orcid>10031947532846007358</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical and Computer Engineering, University of Birjand, Birjand, Iran </affiliation>
	<affiliation_fa>دانشکده مهندسی برق و کامپیوتر -دانشگاه بیرجند-بیرجند- ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
